重要文件

C5151

Sigma-Aldrich

3-氨基甲酰-PROXYL

同義詞:

3-氨基甲酰-2,2,5,5-四甲基-1-吡咯烷氧基, 3-氨基甲酰-2,2,5,5-四甲基四氢吡咯氮氧自由基

登入查看組織和合約定價


About This Item

經驗公式(希爾表示法):
C9H17N2O2
CAS號碼:
分子量::
185.24
EC號碼:
MDL號碼:
分類程式碼代碼:
12352000
PubChem物質ID:
NACRES:
NA.22

形狀

powder

mp

173-175 °C (lit.)

儲存溫度

2-8°C

SMILES 字串

CC1(C)CC(C(N)=O)C(C)(C)N1[O]

InChI

1S/C9H17N2O2/c1-8(2)5-6(7(10)12)9(3,4)11(8)13/h6H,5H2,1-4H3,(H2,10,12)

InChI 密鑰

XNNPAWRINYCIHL-UHFFFAOYSA-N

尋找類似的產品? 前往 產品比較指南

應用

自旋标记物,用于通过电子自旋共振成像进行自由基的体内无创检测。

儲存類別代碼

11 - Combustible Solids

水污染物質分類(WGK)

WGK 3

閃點(°F)

Not applicable

閃點(°C)

Not applicable


從最近期的版本中選擇一個:

分析證明 (COA)

Lot/Batch Number

未看到正確版本?

如果您需要一個特定的版本,您可以透過批號來尋找特定憑證。

已經擁有該產品?

您可以在文件庫中找到最近購買的產品相關文件。

存取文件庫

客戶也查看了

Aki Hirayama et al.
American journal of physiology. Renal physiology, 288(3), F597-F603 (2004-11-13)
Oxidative stress during ischemia-reperfusion acute renal failure (IR-ARF) was noninvasively evaluated with in vivo electron paramagnetic resonance (EPR) imaging. Female ICR mice underwent left nephrectomy and 30-min ischemia-reperfusion of the right kidney. Oxidative stress was evaluated as organ reducing activity
Shingo Matsumoto et al.
Magnetic resonance in medicine, 57(4), 806-811 (2007-03-29)
The present study describes the advantageous application of a surface coil to electron paramagnetic resonance (EPR) irradiation in Overhauser-enhanced MRI (OMRI). OMRI is a double-resonance method for imaging free radicals based on the Overhauser effect. Proton NMR images are recorded
Ken-Ichi Yamada et al.
Antioxidants & redox signaling, 6(3), 605-611 (2004-05-08)
In vivo electron paramagnetic resonance (EPR) with nitroxyl spin probes has been used for the evaluation of in vivo free radical reactions and redox status in living animals. The aim of this study was to clarify the location of free
A Milton Franklin Benial et al.
Journal of magnetic resonance (San Diego, Calif. : 1997), 182(2), 273-282 (2006-08-01)
DNP parameters relevant to Overhauser-enhanced magnetic resonance imaging (OMRI) are reported for a few nitroxyl radicals and their corresponding (15)N and (2)H enriched analogues, used in simultaneous imaging by OMRI. DNP enhancement was measured at 14.529 mT, using a custom-built
Keizo Takeshita et al.
Free radical biology & medicine, 40(5), 876-885 (2006-03-08)
Although free radicals may be involved in various types of UV-induced injuries, only a few in vivo studies of the generation of free radicals, including oxygen radicals, during exposure to ultraviolet light (UV) have been reported. In this study, the

我們的科學家團隊在所有研究領域都有豐富的經驗,包括生命科學、材料科學、化學合成、色譜、分析等.

聯絡技術服務