跳轉至內容
Merck
全部照片(2)

重要文件

92332

Supelco

氯离子载体 IV

Selectophore

同義詞:

4,5-双-[N′-(丁基)硫脲基]-2,7-二叔丁基-9,9-二甲基氧杂蒽

登入查看組織和合約定價


About This Item

經驗公式(希爾表示法):
C33H50N4OS2
CAS號碼:
分子量::
582.91
MDL號碼:
分類程式碼代碼:
26111700
PubChem物質ID:
NACRES:
NB.61

等級

for ion-selective electrodes

品質等級

產品線

Selectophore

形狀

powder

SMILES 字串

CCCCNC(=S)Nc1cc(cc2c1Oc3c(NC(=S)NCCCC)cc(cc3C2(C)C)C(C)(C)C)C(C)(C)C

InChI

1S/C33H50N4OS2/c1-11-13-15-34-29(39)36-25-19-21(31(3,4)5)17-23-27(25)38-28-24(33(23,9)10)18-22(32(6,7)8)20-26(28)37-30(40)35-16-14-12-2/h17-20H,11-16H2,1-10H3,(H2,34,36,39)(H2,35,37,40)

InChI 密鑰

GYGZJHGSLBVTPV-UHFFFAOYSA-N

一般說明

请访问我们的 传感器应用页面 以了解更多信息。

應用

精选应用实例

法律資訊

Selectophore is a trademark of Merck KGaA, Darmstadt, Germany

儲存類別代碼

11 - Combustible Solids

水污染物質分類(WGK)

WGK 3

閃點(°F)

Not applicable

閃點(°C)

Not applicable

個人防護裝備

Eyeshields, Gloves, type N95 (US)


從最近期的版本中選擇一個:

分析證明 (COA)

Lot/Batch Number

未看到正確版本?

如果您需要一個特定的版本,您可以透過批號來尋找特定憑證。

已經擁有該產品?

您可以在文件庫中找到最近購買的產品相關文件。

存取文件庫

客戶也查看了

Wenjun Di et al.
Analytical methods : advancing methods and applications, 12(11), 1441-1448 (2020-04-01)
Personalized approaches for continuous monitoring of chloride levels are potentially valuable for evaluating the efficacy of new treatments of genetic disorders such as cystic fibrosis. In this report, we validated optode-based nanosensors for real-time chloride monitoring in the interstitial fluid
Chloride ionophore, detection limit ~0.0000065 M chloride. Detection of chloride in biological samples.
K.P. Xiao et al.
Analytical Chemistry, 69, 1038-1038 (1997)
Strong Hydrogen Bond-Mediated Complexation of H2PO4- by Neutral Bis-Thiourea Hosts
P. Buhlmann et al.
Tetrahedron, 53, 1647-1647 (1997)
Antra Ganguly et al.
Sensors (Basel, Switzerland), 19(20) (2019-10-28)
This work demonstrates a novel electrochemical biosensor for the detection of chloride ion levels in ultra-low volumes (1-3 microliters) of passively expressed human sweat. We present here a hydration monitor that the pediatric, geriatric, and other immune-compromised or physically inactive/sedentary
Antra Ganguly et al.
SLAS technology, 25(1), 25-32 (2019-10-17)
Misclassification of an acute disease condition as chronic and vice versa by electrochemical sweat biomarker sensors can cause significant psychological, emotional, and financial stress among patients. To achieve higher accuracy in distinguishing between a chronic condition and an acute condition

我們的科學家團隊在所有研究領域都有豐富的經驗,包括生命科學、材料科學、化學合成、色譜、分析等.

聯絡技術服務