跳轉至內容
Merck
全部照片(1)

重要文件

73732

Supelco

2-硝基苯辛醚

Selectophore, ≥99.0%

同義詞:

1-硝基-2-辛氧基苯

登入查看組織和合約定價


About This Item

線性公式:
O2NC6H4O(CH2)7CH3
CAS號碼:
分子量::
251.32
Beilstein:
2529905
EC號碼:
MDL號碼:
分類程式碼代碼:
26111700
PubChem物質ID:
NACRES:
NB.61

等級

for ion-selective electrodes

品質等級

產品線

Selectophore

化驗

≥99.0% (GC)
≥99.0%

形狀

liquid

折射率

n20/D 1.508 (lit.)
n20/D 1.511

bp

197-198 °C/11 mmHg (lit.)

密度

1.04 g/mL at 25 °C (lit.)

SMILES 字串

CCCCCCCCOc1ccccc1[N+]([O-])=O

InChI

1S/C14H21NO3/c1-2-3-4-5-6-9-12-18-14-11-8-7-10-13(14)15(16)17/h7-8,10-11H,2-6,9,12H2,1H3

InChI 密鑰

CXVOIIMJZFREMM-UHFFFAOYSA-N

尋找類似的產品? 前往 產品比較指南

一般說明

2-硝基苯基辛基醚(NPOE)通常用于液/液界面中的离子转移。它的水溶解度低、蒸气压低并且毒性低于其他有机溶剂。它是离子溶质的良好溶剂,因为它具有高摩尔体积和中等介电常数。
请访问我们的 传感器应用门户网站,了解更多信息。

應用

NPOE被用作PVC膜阴离子表面活性剂选择性电极的增塑剂。

特點和優勢

可用作三醋酸纤维素膜的增塑剂,使得金属阳离子不可透过但允许阴离子交换。

法律資訊

Selectophore is a trademark of Merck KGaA, Darmstadt, Germany

儲存類別代碼

10 - Combustible liquids

水污染物質分類(WGK)

WGK 3

閃點(°F)

235.4 °F - closed cup

閃點(°C)

113 °C - closed cup

個人防護裝備

Eyeshields, Gloves


從最近期的版本中選擇一個:

分析證明 (COA)

Lot/Batch Number

未看到正確版本?

如果您需要一個特定的版本,您可以透過批號來尋找特定憑證。

已經擁有該產品?

您可以在文件庫中找到最近購買的產品相關文件。

存取文件庫

Molecular dynamics study of 2-nitrophenyl octyl ether and nitrobenzene.
Jorge, Miguel, et al.
The Journal of Physical Chemistry B, 110.25, 12530-12538 (2006)
A new ion-selective electrode for anionic surfactants.
Segui MA
Talanta, 71(1), 333-338 (2007)
Xiaohui Chen et al.
Journal of experimental botany, 69(21), 5279-5291 (2018-08-14)
To develop elite crops with low cadmium (Cd), a fundamental understanding of the mechanism of Cd uptake by crop roots is necessary. Here, a new mechanism for Cd2+ entry into rice root cells was investigated. The results showed that Cd2+
A R Pereira et al.
Analytical and bioanalytical chemistry, 412(15), 3629-3637 (2020-04-03)
Histamine intolerance results from a disequilibrium of accumulated histamine and the capacity for histamine degradation. An impaired histamine degradation based on reduced DAO activity and the resulting histamine excess may cause numerous symptoms mimicking an allergic reaction. For that, the
Jiahong Lei et al.
Analytica chimica acta, 858, 60-65 (2015-01-20)
A flow injection system incorporated with a polycation-sensitive polymeric membrane electrode in the flow cell is proposed for potentiometric determination of heparin. An external current in nano-ampere scale is continuously applied across the polymeric membrane for controlled release of protamine

我們的科學家團隊在所有研究領域都有豐富的經驗,包括生命科學、材料科學、化學合成、色譜、分析等.

聯絡技術服務