跳轉至內容
Merck
全部照片(1)

重要文件

F-017

Supelco

(±)-Flecainide solution

1.0 mg/mL in methanol, ampule of 1 mL, certified reference material, Cerilliant®

登入查看組織和合約定價


About This Item

經驗公式(希爾表示法):
C17H20F6N2O3
CAS號碼:
分子量::
414.34
EC號碼:
MDL號碼:
分類程式碼代碼:
41116107
PubChem物質ID:
NACRES:
NA.24

等級

certified reference material

形狀

liquid

特點

Snap-N-Spike®/Snap-N-Shoot®

包裝

ampule of 1 mL

製造商/商標名

Cerilliant®

濃度

1.0 mg/mL in methanol

技術

gas chromatography (GC): suitable
liquid chromatography (LC): suitable

應用

clinical testing

形式

single component solution

儲存溫度

−20°C

SMILES 字串

O=C(NCC1CCCCN1)C2=CC(OCC(F)(F)F)=CC=C2OCC(F)(F)F

InChI

1S/C17H20F6N2O3/c18-16(19,20)9-27-12-4-5-14(28-10-17(21,22)23)13(7-12)15(26)25-8-11-3-1-2-6-24-11/h4-5,7,11,24H,1-3,6,8-10H2,(H,25,26)

InChI 密鑰

DJBNUMBKLMJRSA-UHFFFAOYSA-N

基因資訊

human ... SCN5A(6331)

一般說明

Flecainide, marketed under trade names such as Almarytm, Apocard, Ecrinal®, and Flécaine, is a class Ic antiarrhythmic drug used to prevent and treat a variety of cardiac arrhythmias. This Certified Spiking Solution® is suitable for use as a starting material in the preparation of calibrators, controls, or linearity standards in flecainide therapeutic drug monitoring methods by LC/MS or LC that ensure patients remain within the drug′s narrow therapeutic range.

法律資訊

CERILLIANT is a registered trademark of Merck KGaA, Darmstadt, Germany
CERTIFIED SPIKING SOLUTION is a registered trademark of Cerilliant Corporation
Ecrinal is a registered trademark of Laboratoires Asepta Corporation Monaco
Snap-N-Shoot is a registered trademark of Cerilliant Corporation
Snap-N-Spike is a registered trademark of Merck KGaA, Darmstadt, Germany

訊號詞

Danger

危險分類

Acute Tox. 3 Dermal - Acute Tox. 3 Inhalation - Acute Tox. 3 Oral - Flam. Liq. 2 - STOT SE 1

標靶器官

Eyes,Central nervous system

儲存類別代碼

3 - Flammable liquids

水污染物質分類(WGK)

WGK 2

閃點(°F)

49.5 °F - closed cup

閃點(°C)

9.7 °C - closed cup


從最近期的版本中選擇一個:

分析證明 (COA)

Lot/Batch Number

It looks like we've run into a problem, but you can still download Certificates of Analysis from our 文件 section.

如果您需要協助,請聯絡 客戶支援

已經擁有該產品?

您可以在文件庫中找到最近購買的產品相關文件。

存取文件庫

客戶也查看了

Heather Ellsworth et al.
Pacing and clinical electrophysiology : PACE, 36(3), e87-e89 (2012-08-14)
Flecainide is a Vaughan Williams Class Ic antidysrhythmic associated with PR, QRS, and QTc prolongation on the electrocardiogram and development of life-threatening cardiac toxicity in overdose. The cornerstone of treatment is fluid resuscitation and the administration of magnesium and sodium
[Flecainide intoxication].
Santiago Nogué et al.
Medicina clinica, 140(1), 46-46 (2012-10-03)
Joseph J Lynch et al.
Journal of cardiovascular pharmacology, 61(3), 226-232 (2012-11-29)
This study explored the intrinsic vasorelaxant and inotropic effects of the mixed potassium and sodium channel blocker atrial antiarrhythmic vernakalant and the class IC antiarrhythmic agent flecainide in human isolated subcutaneous resistance artery and in ventricular trabecular muscle preparations. At
Antiarrhythmic drug treatment after cardioversion of atrial fibrillation.
Marcelle D Smit et al.
Lancet (London, England), 380(9852), 1467-1467 (2012-10-30)
ECG diagnosis: flecainide toxicity.
Joel T Levis
The Permanente journal, 16(4), 53-53 (2012-12-20)

文章

For efficient therapeutic drug monitoring, it is important for clinicians to have access to fast and robust analytical methods for accurate assessment of drug efficacy. Industrial trends toward highly specific LC/MS applications over traditional immunoassay have resulted in the need for high-speed chromatographic assays along with simplified sample preparation methods.

For efficient therapeutic drug monitoring, it is important for clinicians to have access to fast and robust analytical methods for accurate assessment of drug efficacy. Industrial trends toward highly specific LC/MS applications over traditional immunoassay have resulted in the need for high-speed chromatographic assays along with simplified sample preparation methods.

Separation of Lidocaine solution, 1.0 mg/mL in methanol, ampule of 1 mL, certified reference material; Amiodarone hydrochloride solution, 1.0 mg/mL in methanol (as free base), ampule of 1 mL, certified reference material; (±)-Flecainide solution, 1.0 mg/mL in methanol, ampule of 1 mL, certified reference material; N-Desethylamiodarone hydrochloride solution, 1.0 mg/mL in methanol (as free base), ampule of 1 mL, certified reference material

The benefit of HILIC over traditional reversed-phase chromatography is two-fold for both sample introduction and analyte detection. First, the high acetonitrile concentration of HILIC mobile phases allows for direct analysis of precipitated plasma samples without the need for additional sample solvent exchange. Second, the high acetonitrile content provides increased analyte response in positive ESI MS detection.

相關內容

HILIC mobile phases consist of a high composition of acetonitrile, which facilitates the direct analysis of precipitated plasma samples without the need for additional sample solvent exchange.

Separation of Amiodarone hydrochloride solution, 1.0 mg/mL in methanol (as free base), ampule of 1 mL, certified reference material; N-Desethylamiodarone hydrochloride solution, 1.0 mg/mL in methanol (as free base), ampule of 1 mL, certified reference material; Lidocaine solution, 1.0 mg/mL in methanol, ampule of 1 mL, certified reference material; (±)-Flecainide solution, 1.0 mg/mL in methanol, ampule of 1 mL, certified reference material

Chromatograms

application for HPLCapplication for HPLC

我們的科學家團隊在所有研究領域都有豐富的經驗,包括生命科學、材料科學、化學合成、色譜、分析等.

聯絡技術服務