跳轉至內容
Merck
全部照片(1)

文件

A-130

Supelco

乙酰芬太尼-13C6 标准液 溶液

50 μg/mL in methanol, certified reference material, ampule of 1 mL, Cerilliant®

同義詞:

Deuterium-Labeled Acetyl Fentanyl Solution

登入查看組織和合約定價


About This Item

經驗公式(希爾表示法):
13C6C15H26N2O
分子量::
328.40
MDL號碼:
分類程式碼代碼:
41116107
PubChem物質ID:
NACRES:
NA.24

等級

certified reference material

品質等級

形狀

liquid

特點

Snap-N-Spike®/Snap-N-Shoot®

包裝

ampule of 1 mL

製造商/商標名

Cerilliant®

drug control

estupefaciente (Spain); Decreto Lei 15/93: Tabela IA (Portugal)

濃度

50 μg/mL in methanol

技術

gas chromatography (GC): suitable
liquid chromatography (LC): suitable

應用

forensics and toxicology

格式

single component solution

儲存溫度

−20°C

InChI

1S/C21H26N2O/c1-18(24)23(20-10-6-3-7-11-20)21-13-16-22(17-14-21)15-12-19-8-4-2-5-9-19/h2-11,21H,12-17H2,1H3

InChI 密鑰

FYIUUQUPOKIKNI-UHFFFAOYSA-N

尋找類似的產品? 前往 產品比較指南

一般說明

Acetyl fentanyl is a designer drug and fentanyl analog with a potency 40 times greater than heroin and 80 times greater than morphine. Acetyl fentanyl has been directly implicated in numerous opiate overdose deaths throughout the United States. This stable-labeled internal standard is suitable for quantification of acetyl fentanyl levels in urine or other matrices by LC/MS or GC/MS for clinical toxicology, forensic analysis, prescription monitoring, or urine drug testing applications. This Certified Spiking Solution® is supplied in a convenient, quantitative, US DEA-exempt solution format and with TK #s for Canadian customers.

法律資訊

CERILLIANT is a registered trademark of Merck KGaA, Darmstadt, Germany
CERTIFIED SPIKING SOLUTION is a registered trademark of Cerilliant Corporation
Snap-N-Shoot is a registered trademark of Cerilliant Corporation
Snap-N-Spike is a registered trademark of Merck KGaA, Darmstadt, Germany

相關產品

產品號碼
描述
訂價

訊號詞

Danger

危險分類

Acute Tox. 3 Dermal - Acute Tox. 3 Inhalation - Acute Tox. 3 Oral - Flam. Liq. 2 - STOT SE 1

標靶器官

Eyes

儲存類別代碼

3 - Flammable liquids

水污染物質分類(WGK)

WGK 2

閃點(°F)

49.5 °F - closed cup

閃點(°C)

9.7 °C - closed cup


分析證明 (COA)

輸入產品批次/批號來搜索 分析證明 (COA)。在產品’s標籤上找到批次和批號,寫有 ‘Lot’或‘Batch’.。

已經擁有該產品?

您可以在文件庫中找到最近購買的產品相關文件。

存取文件庫

Pilar Mañas et al.
Applied and environmental microbiology, 70(3), 1545-1554 (2004-03-10)
The relationship between a loss of viability and several morphological and physiological changes was examined with Escherichia coli strain J1 subjected to high-pressure treatment. The pressure resistance of stationary-phase cells was much higher than that of exponential-phase cells, but in

我們的科學家團隊在所有研究領域都有豐富的經驗,包括生命科學、材料科學、化學合成、色譜、分析等.

聯絡技術服務