跳轉至內容
Merck
全部照片(1)

重要文件

T39853

Sigma-Aldrich

甲苯-2,4-二异氰酸酯

95%

同義詞:

2,4-二异氰酸甲苯酯, 4-甲基-1,3-亚苯基二异氰酸酯, BASF LUPRANATE T80, TDI, 二异氰酸甲苯酯

登入查看組織和合約定價


About This Item

線性公式:
CH3C6H3(NCO)2
CAS號碼:
分子量::
174.16
Beilstein:
744602
EC號碼:
MDL號碼:
分類程式碼代碼:
12162002
PubChem物質ID:
NACRES:
NA.23

蒸汽密度

6 (vs air)

蒸汽壓力

0.03 mmHg ( 25 °C)

化驗

95%

自燃溫度

>1148 °F

expl. lim.

9.5 %

雜質

4% 2,6-isomer

折射率

n20/D 1.568 (lit.)

bp

115-120 °C/10 mmHg (lit.)

mp

20-22 °C (lit.)

密度

1.214 g/mL at 25 °C

儲存溫度

2-8°C

SMILES 字串

Cc1ccc(cc1N=C=O)N=C=O

InChI

1S/C9H6N2O2/c1-7-2-3-8(10-5-12)4-9(7)11-6-13/h2-4H,1H3

InChI 密鑰

DVKJHBMWWAPEIU-UHFFFAOYSA-N

尋找類似的產品? 前往 產品比較指南

應用

用于制备聚氨酯和大环冠醚。

象形圖

Skull and crossbonesHealth hazard

訊號詞

Danger

危險分類

Acute Tox. 1 Inhalation - Aquatic Chronic 3 - Carc. 2 - Eye Irrit. 2 - Resp. Sens. 1 - Skin Irrit. 2 - Skin Sens. 1 - STOT SE 3

標靶器官

Respiratory system

儲存類別代碼

6.1A - Combustible acute toxic Cat. 1 and 2 / very toxic hazardous materials

水污染物質分類(WGK)

WGK 2

閃點(°F)

269.6 °F - closed cup

閃點(°C)

132 °C - closed cup

個人防護裝備

Eyeshields, Faceshields, Gloves, type ABEK (EN14387) respirator filter


從最近期的版本中選擇一個:

分析證明 (COA)

Lot/Batch Number

未看到正確版本?

如果您需要一個特定的版本,您可以透過批號來尋找特定憑證。

已經擁有該產品?

您可以在文件庫中找到最近購買的產品相關文件。

存取文件庫

R S Labow et al.
Biomaterials, 16(1), 51-59 (1995-01-01)
The biostability of polyurethanes was evaluated using a human neutrophil cell culture. The polymers were synthesized with 14C radiolabelled components incorporated into the polyurethane chain and the amount of radiolabel released during exposure to cells and medium was used as
J. Incl. Phenom. Mol. Recog. Chem., 17, 249-249 (1994)
Olov Collste et al.
Journal of cardiac failure, 20(12), 968-972 (2014-10-01)
Our objective was to investigate whether dobutamine stress echocardiography (DSE) could induce abnormal cardiac function in takotsubo stress cardiomyopathy (TSC) patients in a stable condition after the acute attack. This was a case-control study and a substudy of the Stockholm
Tatiana Kuznetsova et al.
American journal of hypertension, 28(4), 535-545 (2014-09-23)
The cardio-renal interaction occurs via hemodynamic and humoral factors. Noninvasive assessment of renal hemodynamics is currently possible by assessment of renal resistive index (RRI) derived from intrarenal Doppler arterial waveforms as ((peak systolic velocity - end-diastolic velocity)/peak systolic velocity). Limited
Norman Mangner et al.
JACC. Cardiovascular imaging, 7(12), 1198-1205 (2014-10-13)
The aim of our study was to assess geometric and functional changes of the heart in obese compared with nonobese children and adolescents. Obesity in children and adolescents has increased over the past decades and is considered a strong risk

我們的科學家團隊在所有研究領域都有豐富的經驗,包括生命科學、材料科學、化學合成、色譜、分析等.

聯絡技術服務