Coverage: 200 cm2 per g (using a 156 mesh polyester screen)
Sheet resistivity:<100 miliohms per square (20 micron thick printed on alumina substrate)
形狀
paste
黏度
2.0-5.5 Pa.s (Haake RS1 C20/2° TiL at 230 sec-1 at 25°C)
相關類別
一般說明
该产品的银与氯化银之比为60/40。
應用
- Highly sensitive determination of heavy metals in water prior to and after remediation using Citrofortunella Microcarpa:该文研究在环境监测用丝网印刷电极中采用银-氯化银(Ag/AgCl)浆料(60:40)(Palisoc et al., 2021)。
- Screen-printed graphite electrodes as low-cost devices for oxygen gas detection in room-temperature ionic liquids:通过将Ag/AgCl浆料(60:40)丝网印刷到柔性膜上制作银/氯化银参比电极,探索它在气体传感技术中的有效作用(Lee et al., 2017)。
- Simple Portable Voltammetric Sensor Using Anodized Screen-Printed Graphene Electrode for the Quantitative Analysis of p-Hydroxybenzoic Acid in Cosmetics:在该研究中,银/氯化银浆料(Ag/AgCl: 60/40)用于提高丝印电极的化妆品分析作用(Charoenkitamorn et al., 2022)。
- Dipstick Sensor Based on Molecularly Imprinted Polymer-Coated Screen-Printed Electrodes for Single-Shot Detection of Glucose in Urine Samples:该研究用丝网印刷到塑料上的银/氯化银(60:40)参比电极用于生物医学应用(Caldara et al., 2023)。
- Simultaneous determination of ascorbic acid, dopamine, and uric acid using graphene quantum dots/ionic liquid modified screen-printed carbon electrode:用碳油墨和银/氯化银(Ag/AgCl)浆料60/40开发先进传感器平台(Kunpatee et al., 2020)。
特點和優勢
产品优势
- 在医学诊断、环境传感器中的应用
- 高电导率
- 低固化温度
準備報告
处理
注意:不建议使用不锈钢网,因为糊状成分在潮湿的情况下会腐蚀性。此外,应使用塑料板刀代替金属刀。
- 丝网印刷设备:半自动、手动
- 油墨屏幕寿命:>3小时
- 筛网类型:聚酯,筛156至230 tpi
注意:不建议使用不锈钢网,因为糊状成分在潮湿的情况下会腐蚀性。此外,应使用塑料板刀代替金属刀。
- 典型干燥条件:在箱式烘箱中60℃干燥30分钟或80℃干燥10分钟。
- 净化溶剂:乙氧基丙醇或浆液
- 基质:聚酯、PVC、聚碳酸酯和氧化铝
法律資訊
Gwent Electronic Materials Ltd(GEM)的产品,隶属于Sun Chemical Corporation
訊號詞
Warning
危險聲明
危險分類
Aquatic Acute 1 - Aquatic Chronic 1 - Met. Corr. 1
儲存類別代碼
8A - Combustible corrosive hazardous materials
水污染物質分類(WGK)
WGK 3
閃點(°F)
192.2 °F
閃點(°C)
89 °C
客戶也查看了
A review of screen-printed silver/silver chloride (Ag/AgCl) reference electrodes potentially suitable for environmental potentiometric sensors.
Sensors and actuators A, Physical, 267, 106-120 (2017)
Fabrication of thick film sensitive RuO2-TiO2 and Ag/AgCl/KCl reference electrodes and their application for pH measurements.
Sensors and Actuators B, Chemical, 204, 57-67 (2014)
Screen printed potentiometric sensor for non-invasive measurement of blood urea in human subjects using reverse iontophoresis.
Electrochemical Society Transactions, 66, 1-22 (2015)
文章
Professor Tokito and Professor Takeda share their new materials, device architecture design principles, and performance optimization protocols for printed and solution-processed, low-cost, highly flexible, organic electronic devices.
我們的科學家團隊在所有研究領域都有豐富的經驗,包括生命科學、材料科學、化學合成、色譜、分析等.
聯絡技術服務