推薦產品
品質等級
化驗
98%
形狀
liquid
光學活性
[α]20/D −45°, c = 3.5 in toluene
光學純度
ee: 95% (GLC)
折射率
n20/D 1.604 (lit.)
bp
106-108 °C/0.16 mmHg (lit.)
密度
1.118 g/mL at 25 °C (lit.)
SMILES 字串
C[C@@H](N=C=O)c1cccc2ccccc12
InChI
1S/C13H11NO/c1-10(14-9-15)12-8-4-6-11-5-2-3-7-13(11)12/h2-8,10H,1H3/t10-/m1/s1
InChI 密鑰
GONOHGQPZFXJOJ-SNVBAGLBSA-N
尋找類似的產品? 前往 產品比較指南
訊號詞
Danger
危險分類
Acute Tox. 3 Oral - Eye Irrit. 2 - Resp. Sens. 1 - Skin Irrit. 2 - Skin Sens. 1 - STOT SE 3
標靶器官
Respiratory system
儲存類別代碼
6.1C - Combustible acute toxic Cat.3 / toxic compounds or compounds which causing chronic effects
水污染物質分類(WGK)
WGK 3
閃點(°F)
200.1 °F - closed cup
閃點(°C)
93.4 °C - closed cup
個人防護裝備
Eyeshields, Faceshields, Gloves, type ABEK (EN14387) respirator filter
分析證明 (COA)
輸入產品批次/批號來搜索 分析證明 (COA)。在產品’s標籤上找到批次和批號,寫有 ‘Lot’或‘Batch’.。
Biomedical chromatography : BMC, 9(3), 140-145 (1995-05-01)
A high-performance liquid chromatographic assay is described for the separation and quantification of nadolol isomers in human plasma. The isomers were quantified using reverse-phase HPLC and fluorometric detection after derivatization with the chiral reagent R(-)-1-(naphthyl)ethylisocyanate [R(-)-NEI]. The N-isopropyl analogue (one
Journal of chromatography. B, Biomedical applications, 672(1), 89-96 (1995-10-06)
A procedure for the concurrent determination of the (+)- and (-)-enantiomers of sotalol in plasma using high-performance liquid chromatography of diastereomeric derivatives is described. Sotalol is extracted from a 0.5-ml aliquot of plasma at pH 9.3 using ethyl acetate. Atenolol
Journal of chromatography, 566(1), 155-162 (1991-05-03)
A sensitive high-performance liquid chromatographic assay was developed for the determination of tocainide enantiomers in plasma. Following extraction of tocainide from plasma, the enantiomers were derivatized with S-(+)-1-(1-naphthyl)ethylisocyanate. The resulting diastereomers were separated and quantified using normal-phase chromatography with fluorescence
Journal of chromatography, 621(2), 225-229 (1993-11-24)
A sensitive, stereospecific high-performance liquid chromatographic assay for oxprenolol enantiomers in rat plasma was developed, using a chiral derivatization agent. Racemic oxprenolol and the internal standard (racemic propranolol) are extracted with dichloromethane after alkalinization of the plasma. Quantitation of R(+)-
Pharmaceutical research, 8(9), 1195-1198 (1991-09-01)
A convenient high-performance liquid chromatographic (HPLC) assay was developed for determination of sotalol (STL) enantiomers in plasma. Following addition of the internal standard (IS; racemic atenolol), enantiomers of STL and IS were extracted using ethyl acetate. After evaporation of the
我們的科學家團隊在所有研究領域都有豐富的經驗,包括生命科學、材料科學、化學合成、色譜、分析等.
聯絡技術服務