跳转至内容
Merck

183350

Supelco

聚甲基丙烯酸乙酯

analytical standard, average Mw 340,000 (Typical), average Mn 126,000 (Typical)

登录查看公司和协议定价


About This Item

线性分子式:
[CH2C(CH3)(CO2C2H5)]n
CAS号:
MDL號碼:
分類程式碼代碼:
41116107
PubChem物質ID:
NACRES:
NA.24

等級

analytical standard

品質等級

形狀

crystalline

分子量

average Mn 126,000 (Typical)
average Mw 340,000 (Typical)

技術

gel permeation chromatography (GPC): suitable

格式

neat

SMILES 字串

CCOC(=O)C(C)=C

InChI

1S/C6H10O2/c1-4-8-6(7)5(2)3/h2,4H2,1,3H3

InChI 密鑰

SUPCQIBBMFXVTL-UHFFFAOYSA-N

正在寻找类似产品? 访问 产品对比指南

應用

Poly(ethyl methacrylate) was used in combination with PVC in preparing new phase-separated polymer electrolyte. It was used to understand the polymer-solvent, polymer-surfactant and solvent-surfactant interaction effects and the intercalation process in nanocomposite preparation method.

儲存類別代碼

10 - Combustible liquids

水污染物質分類(WGK)

WGK 3

閃點(°F)

Not applicable

閃點(°C)

Not applicable


从最新的版本中选择一种:

分析证书(COA)

Lot/Batch Number

没有发现合适的版本?

如果您需要特殊版本,可通过批号或批次号查找具体证书。

已有该产品?

在文件库中查找您最近购买产品的文档。

访问文档库

其他客户在看

Slide 1 of 1

1 of 1

Solution intercalation of polystyrene and the comparison with poly (ethyl methacrylate).
Li, Yuqin, and Hatsuo Ishida.
Polymer, 44.21, 6571-6577 (2003)
Phase-separated polymer electrolyte based on poly (vinyl chloride)/poly (ethyl methacrylate) blend.
Han, Hae-Sook, et al.
Journal of Power Sources, 112.2, 461-468 (2002)
Amiralireza Khaledi et al.
Indian journal of dental research : official publication of Indian Society for Dental Research, 22(4), 499-504 (2011-11-30)
The aim of this study was to determine the effect of disinfectant procedures on the dimensional stability and surface quality of a tissue conditioner used as a functional impression material. A tissue conditioner (Visco-gel) used as a functional impression material
Yutaka Takahashi et al.
Gerodontology, 29(2), e1086-e1091 (2012-01-21)
This study investigated the fracture resistance of maxillary acrylic resin complete dentures subjected to long-term water immersion. Maxillary acrylic resin complete dentures were fabricated from five denture base resins. Half of the dentures were stored in water for 50 h
Komal Ladha et al.
General dentistry, 60(3), e166-e169 (2012-05-25)
Providing a complete denture for a patient with an atrophic mandibular ridge presents a unique challenge for dentists. Retention, stability, and support must be considered when fabricating and fitting a complete denture. This article highlights the use of the neutral

我们的科学家团队拥有各种研究领域经验,包括生命科学、材料科学、化学合成、色谱、分析及许多其他领域.

联系技术服务部门