跳转至内容
Merck
所有图片(2)

Key Documents

RKTX2MAG-37K

Millipore

MILLIPLEX® 大鼠肾毒性磁珠面板2-毒性多重测定

The analytes available for this multiplex kit are: Albumin, AGP, ß2M, Cystatin C, EGF, Lipocalin-2/NGAL.

登录查看公司和协议定价


About This Item

分類程式碼代碼:
12161503
eCl@ss:
32161000
NACRES:
NA.84

品質等級

物種活性

rat

製造商/商標名

Milliplex®

assay range

accuracy: 70-123%
standard curve range: 0.00-2 ng/mL
(EGF)

standard curve range: 0.01-10 ng/mL
(Lipocalin-2/NGAL)

standard curve range: 0.01-8 ng/mL
(Cystatin C)

standard curve range: 0.48-350 ng/mL
(β2M)

standard curve range: 1.37-1,000 ng/mL
(AGP)

standard curve range: 10.97-8,000 ng/mL
(Albumin)

inter-assay cv: <15%
intra-assay cv: <10%
(All other analytes)

inter-assay cv: <20%
intra-assay cv: <15%
(AGP)

技術

multiplexing: suitable

檢測方法

fluorometric (Luminex xMAP)

運輸包裝

wet ice

一般說明

MILLIPLEX® 大鼠肾毒性磁珠面板1 & 2,加上微珠形式的Luminex® xMAP®平台,使您能够专注于发现,从而获得理想的速度和灵敏度优势,允许同时定量多重检测多种分析物,从而可以显著提高生产力。

面板类型:毒性

特異性

针对一种分析物的抗体与该组中的任何其他分析物之间不存在或可忽略的交叉反应性。

應用

  • 分析物:α-1酸性糖蛋白(AGP)、白蛋白、ß2M、胱抑素C、EGF、Lipocalin-2/NGAL
  • 推荐的样品类型:尿液
  • 推荐的样品稀释度:1:500
  • 分析运行时间:过夜
  • 研究类别:毒性

特點和優勢

通过在此面板中选择可用的分析物来设计多重试剂盒。

包裝

单个试剂盒即可满足您的所有需求。

儲存和穩定性

试剂盒组分建议的存储温度为2-8°C。

其他說明

灵敏度:有关单个分析物的灵敏度,请参见试剂盒方案。

法律資訊

Luminex is a registered trademark of Luminex Corp
MILLIPLEX is a registered trademark of Merck KGaA, Darmstadt, Germany
xMAP is a registered trademark of Luminex Corp

免責聲明

除非我们的产品目录或产品附带的其他公司文档另有说明,否则我们的产品仅供研究使用,不得用于任何其他目的,包括但不限于未经授权的商业用途、体外诊断用途、离体或体内治疗用途或任何类型的消费或应用于人类或动物。

象形圖

Skull and crossbonesEnvironment

訊號詞

Danger

危險分類

Acute Tox. 3 Dermal - Acute Tox. 4 Inhalation - Acute Tox. 4 Oral - Aquatic Chronic 2 - Eye Irrit. 2 - Skin Irrit. 2 - Skin Sens. 1 - STOT SE 3

標靶器官

Respiratory system

儲存類別代碼

6.1C - Combustible acute toxic Cat.3 / toxic compounds or compounds which causing chronic effects


分析证书(COA)

输入产品批号来搜索 分析证书(COA) 。批号可以在产品标签上"批“ (Lot或Batch)字后找到。

已有该产品?

在文件库中查找您最近购买产品的文档。

访问文档库

Michael J Coyne et al.
PloS one, 17(5), e0269085-e0269085 (2022-05-28)
Symmetric dimethylarginine (SDMA) is a serum biomarker of excretory renal function which consistently correlates with glomerular filtration rate (GFR) across multiple species including rats, dogs, and humans. In human and veterinary clinical settings SDMA demonstrates enhanced sensitivity for detection of
Kidney biomarkers in MCPA-induced acute kidney injury in rats: reduced clearance enhances early biomarker performance.
Wunnapuk, K; Liu, X; Gobe, GC; Endre, ZH; Peake, PW; Grice, JE; Roberts, MS; Buckley, NA
Toxicology Letters null
Iwan P Williams et al.
mAbs, 12(1), 1685349-1685349 (2019-11-27)
IgE monoclonal antibodies hold great potential for cancer therapy. Preclinical in vivo systems, particularly those in which the antibody recognizes the host species target antigen and binds to cognate Fc receptors, are often the closest approximation to human exposure and
Nadeeka S Udawatte et al.
Frontiers in pharmacology, 11, 511-511 (2020-05-12)
Candida albicans is the major fungal species associated with superficial mucosal infections such as oral candidiasis as well as systemic mycoses with high morbidity and mortality. On top of the rising drug resistance, currently available antifungal agents have significant adverse
Klintean Wunnapuk et al.
Toxicology letters, 225(1), 192-200 (2013-12-24)
Accidental or intentional ingestion of glyphosate surfactant-based herbicides, like Roundup(®), leads to nephrotoxicity as well as death. In this study, a panel of kidney injury biomarkers was evaluated in terms of suitability to detect acute kidney injury and dysfunction. The

相关内容

Learn the benefits of using biomarker detection multiplex immunoassays for laboratory, companion, and agricultural animal research and explore MILLIPLEX® multiplex assays for veterinary medicine and animal health research.

我们的科学家团队拥有各种研究领域经验,包括生命科学、材料科学、化学合成、色谱、分析及许多其他领域.

联系技术服务部门