跳转至内容
Merck

601411

Sigma-Aldrich

氟化锂-6Li

95 atom % 6Li, 99% (CP)

登录查看公司和协议定价


About This Item

线性分子式:
6LiF
CAS号:
分子量:
25.01
EC號碼:
MDL號碼:
分類程式碼代碼:
12352302
PubChem物質ID:
NACRES:
NA.12

同位素純度

95 atom % 6Li

品質等級

化驗

99% (CP)

形狀

solid

mp

842 °C

質量偏移

M-1

儲存溫度

room temp

SMILES 字串

[6Li+].[F-]

InChI

1S/FH.Li/h1H;/q;+1/p-1/i;1-1

InChI 密鑰

PQXKHYXIUOZZFA-HCMAANCNSA-M

正在寻找类似产品? 访问 产品对比指南

包裝

这种产品可以散装供应,并可按需包装。有关定价、供货和包装的信息,请联系稳定同位素客户服务

象形圖

Skull and crossbonesHealth hazard

訊號詞

Danger

危險聲明

危險分類

Acute Tox. 3 Oral - Lact. - Repr. 2

儲存類別代碼

6.1D - Non-combustible acute toxic Cat.3 / toxic hazardous materials or hazardous materials causing chronic effects

水污染物質分類(WGK)

WGK 3

閃點(°F)

Not applicable

閃點(°C)

Not applicable


历史批次信息供参考:

分析证书(COA)

Lot/Batch Number

没有发现合适的版本?

如果您需要特殊版本,可通过批号或批次号查找具体证书。

已有该产品?

在文件库中查找您最近购买产品的文档。

访问文档库

其他客户在看

Slide 1 of 3

1 of 3

F Bonfigli et al.
Giornale italiano di medicina del lavoro ed ergonomia, 33(3 Suppl), 391-394 (2011-07-01)
Lithium fluoride is a well known material used for dosimetry. In the last years it was proposed and tested also as imaging detector for X-ray microscopy. Optical microscopy represents the oldest and most used imaging technique for medicine and cell
A I Abd El-Hafez et al.
Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine, 69(10), 1533-1539 (2011-07-05)
Due to their sensitivity, signal reproducibility and stability, lithium fluoride thermoluminescence dosimeters are widely used in many applications. It was noticed that post-irradiation glow curves of LiF dosimeters that had undergone pre-irradiation background dose measurements dramatically differed from the curves
R Takam et al.
Radiation protection dosimetry, 150(1), 22-33 (2011-08-30)
(6)LiF:Mg,Cu,P and (7)LiF:Mg,Cu,P glass-rod thermoluminescent dosemeters (TLDs) were used for measurements of out-of-field photon and neutron doses produced by Varian iX linear accelerator. Both TLDs were calibrated using 18-MV X-ray beam to investigate their dose-response sensitivity and linearity. CR-39 etch-track
Thorsten Grünheid et al.
American journal of orthodontics and dentofacial orthopedics : official publication of the American Association of Orthodontists, its constituent societies, and the American Board of Orthodontics, 141(4), 436-443 (2012-04-03)
Cone-beam computed tomography (CBCT) has become a routine imaging modality for many orthodontic clinics. However, questions remain about the amount of radiation patients are exposed to during the scans. This study determined the amounts of radiation potentially absorbed by a
Christian Bernhardsson et al.
Health physics, 103(6), 740-749 (2012-11-01)
Laboratory studies have shown that ordinary household salt (NaCl) exhibits several promising properties for retrospective dosimetry; e.g., a linear dose response and a low detection limit, down to a few mGy or even less. In an attempt to test NaCl

我们的科学家团队拥有各种研究领域经验,包括生命科学、材料科学、化学合成、色谱、分析及许多其他领域.

联系技术服务部门