- A diffusive sampler for personal monitoring of toluene diisocyanate (TDI) exposure; Part II: Laboratory and field evaluation of the dosimeter.
A diffusive sampler for personal monitoring of toluene diisocyanate (TDI) exposure; Part II: Laboratory and field evaluation of the dosimeter.
American Industrial Hygiene Association journal (1989-01-01)
R J Rando, Y Y Hammad, S N Chang
PMID2539006
ABSTRAKT
A passive monitor for TDI which utilizes microporous Teflon diffusion membranes and a 0.5% sulfuric acid (H2SO4) absorbing medium was evaluated. The collection rate of TDI is proportional to exposure dose from 10 to at least 300 ppb.hr, and response is equivalent for 2,4- and 2,6-TDI. Collection rate is independent of humidity and normal atmospheric pressure variations, while temperature causes a decrease of 1.0% per degree centigrade. Negative interference caused by ambient nitrogen dioxide (NO2) is eliminated by addition of sulfamic acid (HSO3 NH2) to the collecting medium. N-ethylmorpholine is a positive interferent. Field testing of the sampler against a reference impinger technique indicated a positive bias when TDI is aerosolized.
MATERIAŁY
Numer produktu
Marka
Opis produktu
SKU
Gabaryty przesyłki
Dostępność
Cena netto
Ilość
SKU
Gabaryty przesyłki
Dostępność
Cena netto
Ilość
SKU
Gabaryty przesyłki
Dostępność
Cena netto
Ilość