Saltar al contenido
Merck
Todas las fotos(1)

Key Documents

GE29275877

Capto HiRes

S 5/50

Sinónimos:

Capto HiRes

Iniciar sesiónpara Ver la Fijación de precios por contrato y de la organización


About This Item

UNSPSC Code:
23151817
NACRES:
NB.21

manufacturer/tradename

Cytiva 29275877

bed H × diam. × volume

(100 mm) (10 mm) (8 mL)
(50 mm) (5 mm) (1 mL)

¿Está buscando productos similares? Visita Guía de comparación de productos

General description

Capto HiRes Q and Capto HiRes S are prepacked columns for high-resolution purification of proteins and other biomolecules by ion exchange chromatography. They are well-suited for the preparation of highly pure proteins for structural studies and for protein analysis.


Capto HiRes ion exchange chromatography resin


The chromatography resins packed in Capto HiRes Q and Capto HiRes S ion exchange columns are based on a high-flow agarose base matrix and a small bead size (average bead size 9 μm).

Capto HiRes Q and Capto HiRes S are strong anion and strong cation exchangers, respectively with ion exchange properties that remain constant during chromatography within the recommended pH range of 2 to 12.

A high-performance IEX column format


Capto HiRes Q and Capto HiRes S IEX resins are prepacked in high-performance Tricorn glass columns of two different sizes. The columns have fittings for simple connection to ÄKTA chromatography systems or equivalent high-performance systems. All column parts are biocompatible.

High-resolution protein purification


In many research areas, for example in structural biology using X-ray crystallography or cryo-electron microscopy (cryo-EM), obtaining homogeneous size and charge of biomolecules is crucial for the elucidation of their structures. High-resolution separation of samples based on their charge properties is essential to secure sample charge homogeneity and success of the study. Capto HiRes columns separate proteins and biomolecules that are very close in net charge, which makes these columns great for these applications.

Protein analysis


Capto HiRes ion exchange columns can be used for protein analysis, in applications such as characterization of target protein charge variants.

Capto Q HiRes and Capto S HiRes replace MonoBeads columns


A separation that worked on a Mono Q or Mono S column may be performed on a Capto HiRes Q or Capto HiRes S column with little modification or optimization. Similar resin selectivity and slightly improved resolution can be expected with the Capto HiRes columns while using the same experimental conditions. The similar selectivity of the two columns ensures a smooth transition even for quality control (QC) applications.

Features and Benefits

  • High resolution columns—for lab scale ion exchange chromatography.
  • Suitable for preparing highly pure proteins—essential in structural studies to perform techniques such as cryo-electron microscopy or protein crystallography.
  • Suitable for protein analysis in research or quality control—for example, for change variants analysis, or for studying homogeneity in expression.
  • High quality column—excellent reproducibility, durability, and high chemical and pH stabilities.
  • Replacement for Mono Qand Mono Scolumns—delivering similar or improved resolution, with easy transition from one column platform to the other.

Legal Information

Capto is a trademark of Cytiva

Storage Class

3 - Flammable liquids

wgk_germany

WGK 1

flash_point_f

Not applicable

flash_point_c

Not applicable


Certificados de análisis (COA)

Busque Certificados de análisis (COA) introduciendo el número de lote del producto. Los números de lote se encuentran en la etiqueta del producto después de las palabras «Lot» o «Batch»

¿Ya tiene este producto?

Encuentre la documentación para los productos que ha comprado recientemente en la Biblioteca de documentos.

Visite la Librería de documentos

Nuestro equipo de científicos tiene experiencia en todas las áreas de investigación: Ciencias de la vida, Ciencia de los materiales, Síntesis química, Cromatografía, Analítica y muchas otras.

Póngase en contacto con el Servicio técnico