콘텐츠로 건너뛰기
Merck
모든 사진(1)

주요 문서

504920

Supelco

Supelclean LC-SCX SPE Tube

bed wt. 100 mg, volume 1 mL, pk of 108

로그인조직 및 계약 가격 보기


About This Item

UNSPSC 코드:
41115712

material

polypropylene tube

특징

endcapped

구성

bed wt., 100 mg

포장

pk of 108

기술

solid phase extraction (SPE): suitable

용적

1 mL

기질 활성군

SCX phase
SCX

직경

40-45 μm

공극 크기

60 Å

응용 분야

food and beverages

분리 기술

ion exchange
ion exchange

유사한 제품을 찾으십니까? 방문 제품 비교 안내

일반 설명

Supelclean LC-SCX SPE Tubes consist of sulfonic acid bonded silica with Na+ counterions. They can be used for the strong cation exchange of cations, antibiotics, drugs, organic bases, amino acids, catecholamines, herbicides, nucleic acids and bases, nucleosides, and surfactants.

애플리케이션

Supelclean LC-SCX SPE Tube may be used for the solid-phase extraction of β-agonist compounds in feed samples and adulterants in slimming functional foods prior to their quantification by chromatographic techniques.

법적 정보

Supelclean is a trademark of Sigma-Aldrich Co. LLC

픽토그램

Exclamation mark

신호어

Warning

유해 및 위험 성명서

Hazard Classifications

Eye Irrit. 2 - Skin Irrit. 2 - STOT SE 3

표적 기관

Respiratory system

Storage Class Code

11 - Combustible Solids

WGK

WGK 3

Flash Point (°F)

Not applicable

Flash Point (°C)

Not applicable


가장 최신 버전 중 하나를 선택하세요:

시험 성적서(COA)

Lot/Batch Number

It looks like we've run into a problem, but you can still download Certificates of Analysis from our 문서 section.

도움이 필요하시면 연락하세요. 고객 지원 부서

이 제품을 이미 가지고 계십니까?

문서 라이브러리에서 최근에 구매한 제품에 대한 문서를 찾아보세요.

문서 라이브러리 방문

이미 열람한 고객

Slide 1 of 1

1 of 1

A GC-EI-MS-MS Method for Simultaneous Determination of Seven Adulterants in Slimming Functional Foods.
Li Y, et al.
Journal of Chromatographic Science, 50(10), 928-933 (2012)
Simultaneous determination of cimaterol, salbutamol, terbutaline and ractopamine in feed by SPE coupled to UPLC.
Qu CH, et al.
Chromatographia, 73(3-4), 243-249 (2011)

문서

SPE retention mechanism in this case is based on the electrostatic attraction of charged functional groups of the analyte(s) to oppositely charged functional groups on the sorbent.

프로토콜

Retention occurs through polar interaction between the sorbent and analytes. Typical sample matrices that can be employed in normal-phase SPE include hydrocarbon or fatty oils diluted in a solvent like hexane, isooctane, chlorinated solvent, THF, diethyl ether, or ethyl acetate.

자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..

고객지원팀으로 연락바랍니다.