콘텐츠로 건너뛰기
Merck
모든 사진(1)

주요 문서

39337

Supelco

Sethoxydim

certified reference material, TraceCERT®, Manufactured by: Sigma-Aldrich Production GmbH, Switzerland

로그인조직 및 계약 가격 보기


About This Item

실험식(Hill 표기법):
C17H29NO3S
CAS Number:
Molecular Weight:
327.48
Beilstein:
8222943
MDL number:
UNSPSC 코드:
41116107
NACRES:
NA.24

Grade

certified reference material

Quality Level

제품 라인

TraceCERT®

grade

TraceCERT®

유통기한

limited shelf life, expiry date on the label

제조업체/상표

Manufactured by: Sigma-Aldrich Production GmbH, Switzerland

저장 온도

−20°C

SMILES string

CCC\C(=N/OCC)C1=C(O)CC(CC(C)SCC)CC1=O

InChI

1S/C17H29NO3S/c1-5-8-14(18-21-6-2)17-15(19)10-13(11-16(17)20)9-12(4)22-7-3/h12-13,19H,5-11H2,1-4H3/b18-14+

InChI key

CSPPKDPQLUUTND-NBVRZTHBSA-N

유사한 제품을 찾으십니까? 방문 제품 비교 안내

관련 카테고리

일반 설명

This certified reference material (CRM) is produced and certified in accordance with ISO/IEC 17025 and ISO 17034. This CRM is traceable to primary material from an NMI, e.g. NIST or NMIJ.
Certified content by quantitative NMR incl. uncertainty and expiry date are given on the certificate.
Download your certificate at: http://www.sigma aldrich.com

Sethoxydim is a selective, systemic, and cyclohexanedione oxime herbicide, absorbed mainly by foliage, and, to a lesser extent, by roots. It is an acetyl CoA carboxylase (ACCase) inhibitor, which inhibits the incorporation of acetate into fatty acids and interferes with the formation of phospholipids used in building new membranes. It is used to control annual and perennial grass weeds (except Poa spp.) in broad-leaved crops, including cotton, oilseed rape, soybeans, sugar beets, fodder beets, sunflowers, spinach, potatoes, tobacco, peanuts, strawberries, alfalfa, flax, and vegetables.
Sethoxydim is not approved for use in the European Union (EU) as a plant protection agent, following Regulation (EC) No. 1107/2009 and repealing Directive 91/414/EEC. But maximum residue levels of 0.05 mg/kg to 10 mg/kg are allowed for the presence of sethoxydim, expressed as a sum of sethoxydim and clethodim including their degradation products, in products of plant and animal origin, according to the EU Reg. No 839/2008.

애플리케이션

The certified reference material (CRM) is intended to be used as a calibrant for chromatography and other analytical techniques.
Sethoxydim CRM may also be used as given below:

  • Simultaneous residue analysis of 379 pesticides in human serum samples using the QuEChERS extraction method and liquid chromatography-tandem mass spectrometry (LC-MS/MS)
  • Method development for multi-residue analysis of pesticides in agricultural water samples, extracted by QuEChERS method using liquid chromatography (LC) with mass spectrometry (MS)
  • Determination of 260 pesticide residues in human urine samples using a scaled-down QuEChERS approach for sample extraction and liquid chromatography-tandem mass spectrometry (LC-MS/MS)
  • Evaluation of liquid chromatography high-resolution mass spectrometry (UHPLC-HRMS) using time-of-flight mass spectrometry as an accurate-mass multi-residue screening method to estimate multi-class organic contaminants in baby food samples
  • Development of a semi-automated method for the analysis of 261 pesticides and 41 environmental contaminants in catfish muscle samples by QuEChERS sample extraction and low pressure-GC-MS/MS and UHPLC-MS/MS, following an automated robotic micro-SPE clean-up
  • Multi-residue analysis of 200 pesticides and 65 environmental contaminants in 10 samples of cattle, swine, and chicken muscles by fast low-pressure gas chromatography (LP-GC-MS/MS) and ultrahigh-performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS)

법적 정보

TraceCERT is a registered trademark of Merck KGaA, Darmstadt, Germany

적합한 제품을 찾을 수 없으신가요?  

당사의 제품 선택기 도구.을(를) 시도해 보세요.

픽토그램

Environment

유해 및 위험 성명서

예방조치 성명서

Hazard Classifications

Aquatic Chronic 2

Storage Class Code

10 - Combustible liquids

WGK

WGK 2

Flash Point (°F)

Not applicable

Flash Point (°C)

Not applicable


가장 최신 버전 중 하나를 선택하세요:

시험 성적서(COA)

Lot/Batch Number

적합한 버전을 찾을 수 없으신가요?

특정 버전이 필요한 경우 로트 번호나 배치 번호로 특정 인증서를 찾을 수 있습니다.

이 제품을 이미 가지고 계십니까?

문서 라이브러리에서 최근에 구매한 제품에 대한 문서를 찾아보세요.

문서 라이브러리 방문

Development and application of a multi-residue method to determine pesticides in agricultural water using quechers extraction and lc-ms/ms analysis
Song NH, et al.
Separations, 7(4), 52-52 (2020)

자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..

고객지원팀으로 연락바랍니다.