콘텐츠로 건너뛰기
Merck
모든 사진(1)

주요 문서

21104

Supelco

GC Stationary Phase

phase OV-1, bottle of 10 g

로그인조직 및 계약 가격 보기


About This Item

UNSPSC 코드:
23151817

Agency

meets requirements for USP G2

Quality Level

포장

bottle of 10 g

파라미터

100-350 °C temp. range

기술

gas chromatography (GC): suitable

기질 활성군

OV-1 phase

solubility

chloroform, toluene: soluble

컬럼 유형

packed GC

일반 설명

GC methods are divided into two classes depending on the nature of stationary phases; gas-solid chromatography (GSC) and gas-liquid chromatography (GLC). GSC has solid adsorptive material and solute particles are removed from mobile phase by electrostatic forces. GLC has a thin layer of liquid coated or bonded on the surface of an inert particle or on the walls of the column where solute particles are retained in the liquid phase based on their partition coefficients. The primary necessity of a stationary phase is to provide sample separation sustaining phase integrity over a reasonable period of time. It should be stable for the chemical and thermal changes. Selectivity, peak symmetry, analysis time, degree of separation, peak tailing are a few parameters that should be considered before choosing a stationary phase. OV-1 is suitable for the separation of drugs, alkaloids, phenols and steroids.
Synthesized specifically to be purer, of narrow molecular weight range, and without trace catalysts or impurities for use as a GC stationary phase.

애플리케이션

OV-1 is suitable as stationary phase for monitoring the urinary excretion in man for pentachlorophenol (PCP) and PCP conjugated to glucuronic acid using gas chromatography with electron capture detection (GC/ECD).

Storage Class Code

10 - Combustible liquids

WGK

WGK 1

Flash Point (°F)

214.0 °F - closed cup

Flash Point (°C)

101.1 °C - closed cup

개인 보호 장비

Eyeshields, Gloves


가장 최신 버전 중 하나를 선택하세요:

시험 성적서(COA)

Lot/Batch Number

죄송합니다. 지금은 이 제품에 대한 COA이(가) 온라인에서 제공되지 않습니다.

도움이 필요하시면 연락하세요. 고객 지원 부서

이 제품을 이미 가지고 계십니까?

문서 라이브러리에서 최근에 구매한 제품에 대한 문서를 찾아보세요.

문서 라이브러리 방문

S Uhl et al.
Archives of toxicology, 58(3), 182-186 (1986-02-01)
Pentachlorophenol (PCP) was given orally to three volunteers at single doses of 3.9, 4.5, 9, and 18.8 mg. Daily urinary excretion of PCP and PCP conjugated to glucuronic acid was monitored using gas chromatography with electron capture detection (GC/ECD). Based
James P. Lodge, Jr.
Methods of Air Sampling and Analysis, 98-98 (1988)
David B. Troy, Paul Beringer
Remington: The Science and Practice of Pharmacy, 605-605 (2006)

자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..

고객지원팀으로 연락바랍니다.