콘텐츠로 건너뛰기
Merck
모든 사진(1)

주요 문서

21032

Supelco

GC Stationary Phase

phase Carbowax 20M, bottle of 50 g

로그인조직 및 계약 가격 보기


About This Item

UNSPSC 코드:
23151817

Agency

meets requirements for USP G16

Quality Level

양식

solid

포장

bottle of 50 g

파라미터

60-225 °C temp. range

기술

gas chromatography (GC): suitable

기질 활성군

Carbowax 20M phase

solubility

chloroform: soluble

McReynolds 상수

17, 86, 48, 69, 56

컬럼 유형

packed GC

일반 설명

GC methods are divided into two classes depending on the nature of stationary phases; gas-solid chromatography (GSC) and gas-liquid chromatography (GLC). GSC has solid adsorptive material and solute particles are removed from mobile phase by electrostatic forces. GLC has a thin layer of liquid coated or bonded on the surface of an inert particle or on the walls of the column where solute particles are retained in the liquid phase based on their partition coefficients. The primary necessity of a stationary phase is to provide sample separation sustaining phase integrity over a reasonable period of time. It should be stable for the chemical and thermal changes. Selectivity, peak symmetry, analysis time, degree of separation, peak tailing are few parameters that should be considered before choosing a stationary phase. Carbowax 20M is a polar liquid phase suitable as stationary phase for gas chromatography. It consists of two units of (HC2-CH2O)600 with OH terminals connected through a hydrophobic portion. This structure of the polymer makes it suitable for being used as a solvent for polar molecules such as cyclodextrin derivatives. It exhibits good selectivity toward alcohols, diols and aromatic isomeric molecules.
Synthesized specifically to be purer, of narrow molecular weight range, and without trace catalysts or impurities for use as a GC stationary phase.

애플리케이션

Carbowax 20M may be used to test different relative amounts of crosslinking reagents by coating the inner wall of the capillary, to optimizing the capillary column performance.

Storage Class Code

11 - Combustible Solids

WGK

WGK 3

Flash Point (°F)

Not applicable

Flash Point (°C)

Not applicable


가장 최신 버전 중 하나를 선택하세요:

시험 성적서(COA)

Lot/Batch Number

It looks like we've run into a problem, but you can still download Certificates of Analysis from our 문서 section.

도움이 필요하시면 연락하세요. 고객 지원 부서

이 제품을 이미 가지고 계십니까?

문서 라이브러리에서 최근에 구매한 제품에 대한 문서를 찾아보세요.

문서 라이브러리 방문

Jaiver Osorio Grisales et al.
Journal of chromatography. A, 1216(40), 6844-6851 (2009-09-01)
This paper reports the study of poly(oxyethylene) as a solvent for heptakis(2,3,6-tri-O-methyl)-beta-cyclodextrin (PM-beta-CD) and the potential of these mixtures for constructing enantioselective gas chromatography columns. Enantioseparations of volatile racemic mixtures using capillaries coated with 10-50% PM-beta-CD diluted in Carbowax 20M
George Charalambous
Chemistry of foods and beverages: Recent developments, 76-76 (1982)
Michael Gratzel
Energy Resour. Photochem. Catal. (M. Gratzel, ed.) (1983)
Nuno I P Valente et al.
Sensors (Basel, Switzerland), 18(8) (2018-07-26)
Cheese prepared from whole milk, raw and pasteurized, were analysed by an electronic nose based on piezoelectric quartz crystals and an electronic tongue based on potentiometric sensors, immediately after their preparation and along ripening (after 7 and 21 days). Whey
James P. Lodge, Jr.
Methods of Air Sampling and Analysis, 98-98 (1988)

자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..

고객지원팀으로 연락바랍니다.