추천 제품
material
RC,GFF,F,F (specially cleaned) separators
Quality Level
Agency
NIOSH 5601
OSHA 62,63,67,70,74
제품 라인
Amberlite™
ORBO™
구성
Bed A, 270 mg
Bed B, 140 mg
포장
pkg of 10 ea
제조업체/상표
ORBO™ 49P
기술
active air sampling: suitable
O.D. × L
13-8 mm × 75 mm , OSHA Versatile Sampler (OVS) Tube
기질
XAD-2 (specially cleaned)
입자 크기
20-40 mesh
응용 분야
air monitoring
environmental
industrial hygiene
유사한 제품을 찾으십니까? 방문 제품 비교 안내
일반 설명
The OSHA Versatile Sampler (OVS) was primarily designed for collection of Organophosphorus pesticides but is suitable for other applications. This specially constructed open glass tube is 75 mm long with a 13-mm outer diameter (O.D.) on the inlet end tapered to 8 mm (O.D.) on the outlet end. The design features a glass filter to trap the aerosols and a two-section sorbent portion to adsorb the vapors. The tube is packed with specially cleaned XAD-2 material and is QA tested to ensure low background interferences. The product is capped at the inlet and outlet to minimize environmental exposure. Meets OSHA and NIOSH method design specifications.
법적 정보
Amberlite is a trademark of DuPont de Nemours, Inc.
ORBO is a trademark of Sigma-Aldrich Co. LLC
Supelpak is a trademark of Sigma-Aldrich Co. LLC
XAD is a registered trademark of The Dow Chemical Company or an affiliated company of Dow
Storage Class Code
10 - Combustible liquids
WGK
WGK 3
Flash Point (°F)
Not applicable
Flash Point (°C)
Not applicable
Choose from one of the most recent versions:
시험 성적서(COA)
Sorry, we don't have COAs for this product available online at this time.
If you need assistance, please contact 고객 지원 부서
이미 열람한 고객
Journal of AOAC International, 80(5), 1091-1097 (1997-11-05)
A method to sample and analyze chlorothalonil and dichlofluanid in greenhouse air was evaluated. Analysis was performed by gas chromatography with electron capture detection and gas chromatography-mass spectrometry. Solid sorbents such as Chromosorb 102, Porapak R, Supelpak-2, Amberlite XAD-2, Amberlite
Journal of chemical ecology, 17(11), 2127-2141 (1991-11-01)
Male American palm weevils (APWs),Rhynchophorus palmarum (L.) produced two sex-specific compounds, which were disclosed by volatile collections on Supelpak-2 and gas chromatography. One was a minor compound, not always detected. The major male-produced volatile was identified as (2E)-6-methyl-2-hepten-4-ol through coupled
Analytica chimica acta, 573-574, 209-215 (2007-08-29)
A methodology is described for greenhouse air analysis by sampling fenhexamid, pyrimethanil, malathion, metalaxyl-M and myclobutanil in solid sorbents. Pesticides were determined by gas chromatography with NP Detector. The trapping efficiency of XAD-2, XAD-4, Supelpak-2, Florisil and C-18 at different
Cognitive processing, 12(1), 13-21 (2010-09-25)
We recorded the pupil diameters of participants performing the words' color-naming Stroop task (i.e., naming the color of a word that names a color). Non-color words were used as baseline to firmly establish the effects of semantic relatedness induced by
Tidsskrift for den Norske laegeforening : tidsskrift for praktisk medicin, ny raekke, 117(7), 972-976 (1997-03-10)
The development of female steroid hormone-related neoplasms such as gynaecologic and mammary cancers is influenced by hormones administered exogenously. Hormonal contraceptives and hormone replacement therapy both affect the risk of developing cancers in the endometrium, cervix, ovarium, and mammary glands.
Chromatograms
suitable for GC, application for air monitoring자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..
고객지원팀으로 연락바랍니다.