추천 제품
vapor density
1.41 (vs air)
Quality Level
vapor pressure
72.8 mmHg ( 20 °C)
설명
suitable for EPA 533
suitable for EPA 537.1
분석
≥99.9% (GC)
형태
liquid
autoignition temp.
973 °F
expl. lim.
16 %
refractive index
n20/D 1.344 (lit.)
bp
81-82 °C (lit.)
mp
−45 °C (lit.)
density
0.786 g/mL at 25 °C (lit.)
적합성
suitable for UHPLC-MS
SMILES string
CC#N
InChI
1S/C2H3N/c1-2-3/h1H3
InChI key
WEVYAHXRMPXWCK-UHFFFAOYSA-N
유사한 제품을 찾으십니까? 방문 제품 비교 안내
일반 설명
LiChrosolv ultra-high purity solvents for PFAS testing are specially designed for this high demanding application. The products will help to reduce background interference and will not contain any of the PFAS compounds above the limit values defined by the EPA 533 and EPA 537.1 methods. This allows reliable and effective testing to facilitate identification and quantitation of PFAS analytes and eliminates the risk of false positive or false negative results in LC-MS/MS analysis.
PFAS tested solvents are used for UHPLC-MS and LC-MS instrumental analysis.
애플리케이션
PFAS tested solvents are qualified for PFAS analysis according to drinking water testing methods EPA 533 and EPA 537.1.
PFAS testing features:
- QC Batch tested 29 PFAS analytes according to EPA 533 (25 analytes) and EPA 537.1 (18 analytes)
- Lot to lot consistency: Multiple batches validated by a third-party accredited testing laboratory and internal laboratories
PFAS testing features:
- QC Batch tested 29 PFAS analytes according to EPA 533 (25 analytes) and EPA 537.1 (18 analytes)
- Lot to lot consistency: Multiple batches validated by a third-party accredited testing laboratory and internal laboratories
특징 및 장점
- ESI/APCI (+) < 2 ppb; ESI/APCI (-) < 10 ppb
- Lowest impurity profile for Interference free baseline
- Borosilicate glass bottles minimize contamination with metal ions
- Lowest levels of trace metal impurities: for minimized metal ion adduct formation <5ppb -
Microfiltration through 0.2 μm filter
- Lowest impurity profile for Interference free baseline
- Borosilicate glass bottles minimize contamination with metal ions
- Lowest levels of trace metal impurities: for minimized metal ion adduct formation <5ppb -
Microfiltration through 0.2 μm filter
법적 정보
Merck/Sigma-Aldrich
LICHROSOLV is a registered trademark of Merck KGaA, Darmstadt, Germany
신호어
Danger
유해 및 위험 성명서
Hazard Classifications
Acute Tox. 4 Dermal - Acute Tox. 4 Inhalation - Acute Tox. 4 Oral - Eye Irrit. 2 - Flam. Liq. 2
Storage Class Code
3 - Flammable liquids
WGK
WGK 2
Flash Point (°F)
35.6 °F - closed cup
Flash Point (°C)
2.0 °C - closed cup
가장 최신 버전 중 하나를 선택하세요:
자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..
고객지원팀으로 연락바랍니다.