추천 제품
종 반응성
human
포장
kit of 96 wells (12 strips x 8 wells)
기술
ELISA: suitable
capture ELISA: suitable
입력
sample type plasma
sample type urine
sample type serum
sample type cell culture supernatant(s)
assay range
inter-assay cv: <12%
intra-assay cv: <10%
sensitivity: 200 pg/mL
standard curve range: 0.343-250 ng/mL
검출 방법
colorimetric
배송 상태
wet ice
저장 온도
−20°C
유전자 정보
human ... PSG2(5670)
일반 설명
The Human CEA (Carcinoembryonic Antigen) ELISA (Enzyme-Linked Immunosorbent Assay) kit is an in vitro enzyme-linked immunosorbent assay for the quantitative measurement of human CEA in serum, plasma, cell culture supernatants and urine.
면역원
Recombinant Human CEA
애플리케이션
Human CEA ELISA Kit has been used to compare the analytical results of paper-based analytical device (PAD)-based sensing platform with commercial enzyme linked immunosorbent asay (ELISA) kits for measuring target carcinoembryonic antigen (CEA) levels. It has also been used to comparatively study the limit of detection (LOD) of the quartz crystal microbalance (QCM) immunosensing method.
기타 정보
A sample Certificate of Analysis is available for this product.
Please type the word sample in the text box provided for lot number.
Please type the word sample in the text box provided for lot number.
신호어
Warning
유해 및 위험 성명서
예방조치 성명서
Hazard Classifications
Met. Corr. 1
Storage Class Code
8A - Combustible corrosive hazardous materials
Analytical chemistry, 89(9), 5152-5160 (2017-04-06)
An all-in-one paper-based analytical device (PAD) was successfully developed for visual fluorescence detection of carcinoembryonic antigen (CEA) on CdTe/CdSe quantum dot (QD)-enzyme-impregnated paper by coupling with a bioresponsive controlled-release system from DNA-gated mesoporous silica nanocontainers (MSNs). The assay was carried
Journal of liposome research, 24(3), 216-222 (2014-03-07)
Thermodynamic analysis of ligand-target binding has been a useful tool for dissecting the nature of the binding mechanism and, therefore, potentially can provide valuable information regarding the utility of targeted formulations. Based on a consistent coupling of antibody-antigen binding and
Nature communications, 9(1), 1743-1743 (2018-05-03)
Microfluidic biochips hold great potential for liquid analysis in biomedical research and clinical diagnosis. However, the lack of integrated on-chip liquid mixing, bioseparation and signal transduction presents a major challenge in achieving rapid, ultrasensitive bioanalysis in simple microfluidic configurations. Here
Talanta, 129, 106-112 (2014-08-17)
Using the role of p-iodophenol in enzyme assay, enhanced 1,1'-oxalyldiimidazole chemiluminescent enzyme immunoassays (ODI-CLEIAs) were developed to consecutively quantify trace levels of triple tumor markers, such as alpha fetoprotein (AFP), carcinoembryonic antigen (CEA), and prostate specific antigen (PSA) in a
자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..
고객지원팀으로 연락바랍니다.