MSRT1

Sigma-Aldrich

MS RT Calibration Mix

Proteomics Retention Time Standard for LC-MS

동의어(들):

Proteomics Retention Time Standard for LC-MS

로그인조직 및 계약 가격 보기


About This Item

UNSPSC 코드:
12352200
NACRES:
NA.24

형태

ready-to-use solution

Quality Level

품질

Proteomics Retention Time Standard for LC-MS

분석물 화학적 분류

amino acids, peptides, proteins

기술

HPLC: suitable
LC/MS: suitable

응용 분야

food and beverages

형식

multi-component solution

저장 온도

−20°C

일반 설명

MSRT1 is an injection-ready standard, and can serve for quick tests of LC-MS platform performance, comparison of LC gradients and columns, monitoring column and system changes. MSRT1 can be used to predict retention times of peptides across LC-MS platforms. MSRT1 is also applicable to multiple reaction monitoring / selected reaction monitoring (MRM / SRM) analysis.

Components:
Each vial contains various amounts of 14 isotopically labeled synthetic peptides dried via vacuum centrifugation. Each peptide is labeled with either a [13C6,15N2] Lysine (+8 Da), a [13C6,15N4] Arginine (+10 Da), or a [13C6,15N] Leucine (+7 Da).

애플리케이션

MS RT Calibration Mix has been used as a reference for iRT (relative retention times) calculations after LC-MS (liquid chromatography–mass spectrometry)/MS analysis. It has been used to check the reliability and specificity of ETD-HCD (electron transfer dissociation-high-energy collisional dissociation) MS3 (mass spectrometry) method for leucine/isoleucine discrimination.
The MS RT Calibration Mix is a LC-MS platform standard intended to test properties such as LC resolution, peptide elution profiles, and retention time prediction. The peptides in MSRT1 are designed to span the normal elution profile of complex proteomic samples. The peptides have been added in various amounts, based on electrospray response, to have relatively similar response and be readily observed.

MSRT1 is an injection-ready standard, and can serve for quick tests of LC-MS platform performance, comparison of LC gradients and columns, monitoring column and system changes. MSRT1 can be used to predict retention times of peptides across LC-MS platforms. MSRT1 is also applicable to multiple reaction monitoring / selected reaction monitoring (MRM / SRM) analysis.

특징 및 장점

General

Complexity

  • Defined mixture gives confidence in your instruments analysis

Easily visualized
  • Distinct LC-MS peak profile of peptides, readily separated with similar responses
  • iRT Table (xls)

Injection-ready
  • Decreases prep time

Qualitative:
  • Defined mixture of 14 stable isotope labeled (SIL) peptides

Quantitative:
MRM settings provided (Skyline, xls)

추천 제품

Discover LiChropur reagents ideal for HPLC or LC-MS analysis

법적 정보

This product is licensed under U.S. Patent No. 7,396,688 and foreign counterparts from E. I. du Pont de Nemours and Company. The purchase of this product conveys to the buyer the nontransferable right to use the purchased amount of the product for research and development only, including services for a third party for consideration. The buyer cannot sell or otherwise transfer this product, its components or materials made using this product or its components to a third party. Information about licenses for excluded uses is available from: E. I. du Pont de Nemours and Company; Attn: Associate Director, Commercial Development; DuPont Experimental Station E268; 200 Powdermill Rd.; Wilmington, DE 19803; 1-877-881-9787 (voice), 1-302-695-1437 (fax), licensing@dupont.com.

Storage Class Code

11 - Combustible Solids

WGK

WGK 2

Flash Point (°F)

Not applicable

Flash Point (°C)

Not applicable


시험 성적서(COA)

제품의 로트/배치 번호를 입력하여 시험 성적서(COA)을 검색하십시오. 로트 및 배치 번호는 제품 라벨에 있는 ‘로트’ 또는 ‘배치’라는 용어 뒤에서 찾을 수 있습니다.

이 제품을 이미 가지고 계십니까?

문서 라이브러리에서 최근에 구매한 제품에 대한 문서를 찾아보세요.

문서 라이브러리 방문

Distinguishing between Leucine and Isoleucine by Integrated LC-MS Analysis Using an Orbitrap Fusion Mass Spectrometer.
Xiao Y, et al.
Analytical Chemistry, 88, 10757-10766 (2016)
Vital Vialas et al.
Journal of proteomics, 152, 138-149 (2016-12-19)
Despite the maturity reached by targeted proteomic strategies, reliable and standardized protocols are urgently needed to enhance reproducibility among different laboratories and analytical platforms, facilitating a more widespread use in biomedical research. To achieve this goal, the use of dimensionless
Yongsheng Xiao et al.
Analytical chemistry, 88(21), 10757-10766 (2016-11-02)
Despite the great success of mass spectrometry (MS) for de novo protein sequencing, Leu and Ile have been generally considered to be indistinguishable by MS because their molecular masses are exactly the same. Positioning of incorrect Leu/Ile residues in variable
A multicentric study to evaluate the use of relative retention times in targeted proteomics.
Vialas V, et al.
Journal of Proteomics, 152, 138-149 (2017)