ligand
quaternary amine
설명
Ion Exchanger Type (value)
포장
pack of 75 mL
제조업체/상표
Cytiva 17-1014-01
기질
6% cross-linked agarose
입자 크기
24-44 μm
평균 부품 크기
34 μm
cleaning in place
1-14
working range
2-12
적합성
suitable for bioprocess medium
관련 카테고리
일반 설명
Q Sepharose High Performance is composed of crosslinked agarose beads with a mean diameter of 34 µm, modified with quaternary (Q) strong anion exchange groups. It is designed for intermediate purification and polishing applications and to be used when resolution and capacity have priority. Q Sepharose High Performance has high chemical stability and withstands effective CIP/sanitization protocols using sodium hydroxide.
Q Sepharose High Performance is available in a range of different bulk pack sizes and convenient pre-packed formats for easy scale-up and process development. As member of the BioProcess resins range, Q Sepharose High Performance meets industrial demands with security of supply and comprehensive technical and regulatory support.
애플리케이션
특징 및 장점
- Strong anion exchanger for intermediate and final polishing steps
- High resolution, high capacity separation with high recovery
- High chemical stability for effective CIP/sanitization
- BioProcess resin supported for industrial applications and well-established in approved processes
- The hydrophilic nature of the base matrix ensures low levels of non-specific binding leading to low levels of host cell-derived impurities in the elution pool.
저장 및 안정성
분석 메모
법적 정보
신호어
Warning
유해 및 위험 성명서
Storage Class Code
3 - Flammable liquids
시험 성적서(COA)
제품의 로트/배치 번호를 입력하여 시험 성적서(COA)을 검색하십시오. 로트 및 배치 번호는 제품 라벨에 있는 ‘로트’ 또는 ‘배치’라는 용어 뒤에서 찾을 수 있습니다.
문서
This page shows Hydrophobic Interaction Chromatography (HIC) in a purification strategy.
Here the correct ways for Column, Media and Sample preparation for Hydrophobic Interaction Chomatography (HIC) with GE Healthcare media are detailed, including sample application, load volume and temperature
This page describes principles and standard conditions for different purification techniques of histidine-tagged proteins using GE Healthcare products.
프로토콜
While ligands contribute significantly to the degree of hydrophobicity of a medium, the matrix can also influence the final selectivity. Chromatography media for hydrophobic interaction are made from porous matrices, chosen for their physical stability, their chemical resistance to stringent cleaning conditions and their low level of non-specific interaction.
This page discusses how to do a purification with SOURCE™ media from GE Healthcare
This page discusses various aspects of sample preparation for chromatographic purification.
자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..
고객지원팀으로 연락바랍니다.