GE17-0727-20

SOURCE 15RPC

Cytiva 17-0727-20, pack of 10 mL

로그인조직 및 계약 가격 보기


About This Item

UNSPSC 코드:
13111000
NACRES:
NA.56

ligand

matrix surface

특징

autoclavable 20 min at 121°C

포장

pack of 10 mL

제조업체/상표

Cytiva 17-0727-20

Matrix

polystyrene/divinylbenzene

평균 부품 크기

15 μm (monosized)

cleaning in place

1-14

작동 범위

1-12

용량

~10 mg binding capacity

적합성

suitable for bioprocess medium

일반 설명

SOURCE 15RPC is designed for reversed phase chromatography (RPC) with full pH range stability and suitable for polishing steps in industrial processes requiring high f low velocities and low back-pressure.
~10 mg BSA /ml medium at 300 cm/h, ~30 mg bacitracin/ml medium at 300 cm/h, ~50 mg insulin/ml medium at 300 cm/h

애플리케이션

SOURCE 15RPC is based on a 15 μm, monosized, rigid polystyrene/divinyl benzene matrix. This gives Low back pressures and high flow rates during operation allowing for high productivity. The 15 μm bead size allows for very high resolution chromatography steps.

High quality assurance standards in combination with the patented production method, particle structure is consistent both bead-to-bead and batch-to-batch.

A controlled pore size distribution and large specific surface area offer excellent capacity for a wide range of molecules, from small peptides and oligonucleotides up to large Proteins. With full pH range stability, SOURCE 15RPC is a strong alternative to silica-based RPC matrices.

SOURCE 15RPC is available in a range of different bulk pack sizes for easy scale-up and process development. As member of the BioProcess media range, SOURCE 15RPC meets industrial demands with security of supply and comprehensive technical and regulatory support.

특징 및 장점

  • Mono-sized 15 μm rigid beads gives Low back pressures and high flow rates allowing for high productivity.
  • Designed for high resolution reversed phase chromatography of Proteins, peptides and oligonucleotides.
  • High chemical stability allowing for wide range of working conditions with good resistance to cleaning conditions at high pH
  • BioProcess medium supported for industrial applications.

저장 및 안정성

Please be aware this product may be shipped 90 days before the expiration date. For more information on the batch specific expiration date, please contact technical service.
Store at 4 to 30 °C (20% Ethanol or 70% Acetonitrile)

분석 메모

To view the Certificate of Analysis for this product, please visit www.cytiva.com.

법적 정보

SOURCE is a trademark of Cytiva

픽토그램

Flame

신호어

Warning

유해 및 위험 성명서

Storage Class Code

3 - Flammable liquids


가장 최신 버전 중 하나를 선택하세요:

시험 성적서(COA)

Lot/Batch Number

죄송합니다. 지금은 이 제품에 대한 COA이(가) 온라인에서 제공되지 않습니다.

도움이 필요하시면 연락하세요. 고객 지원 부서

이 제품을 이미 가지고 계십니까?

문서 라이브러리에서 최근에 구매한 제품에 대한 문서를 찾아보세요.

문서 라이브러리 방문

문서

Poor-quality eluent components can cause a phenomenon referred to as “ghosting”. Trace levels of organic impurities bind to the medium, concentrating during equilibration and sample application. When elution begins, these contaminants appear in the chromatogram as unknown, or “ghost” peaks.

This page discusses column packing and preparation techniques for reverse phase chromatography

This page shows Hydrophobic Interaction Chromatography (HIC) in a purification strategy.

프로토콜

In this section the practical aspect of Reverse Phased Chromatography ( RPC) is discussed including media and column selection and eluent selection and preparation.

자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..

고객지원팀으로 연락바랍니다.