추천 제품
Quality Level
형태
liquid
density
1.85 g/mL at 25 °C (lit.)
응용 분야
hematology
histology
InChI
1S/C10F22/c11-1(12,3(15,16)5(19,20)7(23,24)9(27,28)29)2(13,14)4(17,18)6(21,22)8(25,26)10(30,31)32
InChI key
BPHQIXJDBIHMLT-UHFFFAOYSA-N
일반 설명
Fluorinert™ FC-40 is a clear, colorless, non-conductive, and non-flammable liquid that is part of the Fluorinert™ family of products manufactured by 3M. It is a perfluorinated fluid that has excellent thermal and chemical stability and has a high electric strength, making it suitable for use as a heat transfer fluid. Fluorinert™ FC-40 has a low boiling point (about 155 °C)It is an immiscible fluorocarbon oil.
애플리케이션
Fluorinert™ FC-40 has been used to evaluate its compatibility with real time quantitative PCR. It has been used in the cytoskeletal contractility assay to deposit samples in dish.
For possible use as a high density chase solution in density gradient studies.
포장
Packaged and distributed by Sigma-Aldrich
기타 정보
A trademark for a liquid mixture of completely fluorinated aliphatic compounds.
법적 정보
Fluorinert is a trademark of 3M Company
Storage Class Code
10 - Combustible liquids
WGK
WGK 2
Flash Point (°F)
Not applicable
Flash Point (°C)
Not applicable
개인 보호 장비
Eyeshields, Gloves, type ABEK (EN14387) respirator filter
시험 성적서(COA)
제품의 로트/배치 번호를 입력하여 시험 성적서(COA)을 검색하십시오. 로트 및 배치 번호는 제품 라벨에 있는 ‘로트’ 또는 ‘배치’라는 용어 뒤에서 찾을 수 있습니다.
이미 열람한 고객
Dielectrophoretic characterization of cells in a stationary nanoliter droplet array with generated chemical gradients.
Biomedical Microdevices, 17, 91-91 (2015)
Scientific reports, 9(1), 7341-7341 (2019-05-16)
The demand to perform forensic DNA profiling outside of centralized laboratories and on the crime scene is increasing. Several criminal investigations would benefit tremendously from having DNA based information available in the first hours rather than days or weeks. However
A quantitative analysis of contractility in active cytoskeletal protein networks.
Biophysical Journal, 94, 3126-3126 (2008)
Influence of segmenting fluids on efficiency, crossing point and fluorescence level in real time quantitative PCR.
Biomedical Microdevices, 8, 59-59 (2006)
Communications biology, 3(1), 736-736 (2020-12-06)
Biomedical research often involves conducting experiments on model organisms in the anticipation that the biology learnt will transfer to humans. Previous comparative studies of mouse and human tissues were limited by the use of bulk-cell material. Here we show that
자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..
고객지원팀으로 연락바랍니다.