추천 제품
제품 라인
BioUltra
형태
viscous liquid
분자량
Mr 285-315
불순물
insoluble matter:, passes filter test
≤0.001% peroxides (as H2O2):
refractive index
n20/D 1.465
pH
5.5-7.0 (25 °C, 50 mg/mL in H2O)
solubility
H2O: 50 mg/mL at 25 °C, clear, colorless
density
1.125 g/mL at 20 °C
음이온 미량물
chloride (Cl-): ≤50 mg/kg
sulfate (SO42-): ≤50 mg/kg
양이온 미량물
Al: ≤5 mg/kg
As: ≤0.1 mg/kg
Ba: ≤5 mg/kg
Bi: ≤5 mg/kg
Ca: ≤10 mg/kg
Cd: ≤5 mg/kg
Co: ≤5 mg/kg
Cr: ≤5 mg/kg
Cu: ≤5 mg/kg
Fe: ≤5 mg/kg
K: ≤200 mg/kg
Li: ≤5 mg/kg
Mg: ≤5 mg/kg
Mn: ≤5 mg/kg
Mo: ≤5 mg/kg
Na: ≤200 mg/kg
Ni: ≤5 mg/kg
Pb: ≤5 mg/kg
Sr: ≤5 mg/kg
Zn: ≤5 mg/kg
λ
50 mg/mL in H2O
UV 흡수
λ: 260 nm Amax: 0.06
λ: 280 nm Amax: 0.03
SMILES string
C(CO)O
InChI
1S/C2H6O2/c3-1-2-4/h3-4H,1-2H2
InChI key
LYCAIKOWRPUZTN-UHFFFAOYSA-N
유사한 제품을 찾으십니까? 방문 제품 비교 안내
애플리케이션
- Development of Lyophilized Eukaryotic Cell-Free Protein Expression System Based on Leishmania tarentolae.: This study explores the use of Poly(ethylene glycol) (PEG) in creating a lyophilized eukaryotic cell-free protein expression system. The research demonstrates how PEG facilitates the stabilization and preservation of cell-free systems, enhancing protein synthesis capabilities for various biochemical applications (Alfaro-Palma et al., 2024).
- High-Contrast Luminescent Immunohistochemistry Using PEGylated Lanthanide Complexes.: The application of PEGylated lanthanide complexes in immunohistochemistry significantly improves the contrast and specificity of luminescent signals. This innovation aids in more accurate biochemical analysis and diagnostics (Su et al., 2022).
- Analyzing Immune Response to Engineered Hydrogels by Hierarchical Clustering of Inflammatory Cell Subsets.: This research investigates the immune responses to PEG-based hydrogels used in tissue engineering. It provides insights into the biocompatibility and inflammatory reactions, essential for designing advanced biomaterials (Fernandez-Yague et al., 2022).
- Person-Specific Biomolecular Coronas Modulate Nanoparticle Interactions with Immune Cells in Human Blood.: The study shows how PEGylation of nanoparticles affects their interaction with immune cells, influencing drug delivery systems and therapeutic efficacy in biochemistry and molecular biology (Ju et al., 2020).
- A Post-Insertion Strategy for Surface Functionalization of Bacterial and Mammalian Cell-Derived Extracellular Vesicles.: This paper discusses the post-insertion method using PEG for surface functionalization of extracellular vesicles, enhancing their potential for targeted drug delivery and biochemical research (Jiang et al., 2021).
Storage Class Code
10 - Combustible liquids
WGK
WGK 1
Flash Point (°F)
281.5 °F - closed cup
Flash Point (°C)
138.6 °C - closed cup
개인 보호 장비
Eyeshields, Gloves, type N95 (US)
시험 성적서(COA)
제품의 로트/배치 번호를 입력하여 시험 성적서(COA)을 검색하십시오. 로트 및 배치 번호는 제품 라벨에 있는 ‘로트’ 또는 ‘배치’라는 용어 뒤에서 찾을 수 있습니다.
이미 열람한 고객
자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..
고객지원팀으로 연락바랍니다.