추천 제품
배송 상태
dry ice
저장 온도
−20°C
일반 설명
The Transcreener® HTS Assay platform overcomes the need for time-consuming, one-off assay development for individual members within a group transfer enzyme family by utilizing a single set of assay reagents that detect an invariant product. The generic nature of the Transcreener® HTS Assay platform eliminates delays involved in assay development for new HTS targets, and greatly simplifies compound and inhibitor profiling across multiple target families.
The Transcreener® GDP Assay is a far-red, competitive fluorescence polarization (FP) assay based on the detection of GDP and therefore is compatible with any enzyme that produces GDP, including GTPases such as CDC42. The Transcreener® GDP Assay is a simple one step homogenous detection assay, and is extremely flexible with regard to GTP concentration (1 to 1,000 μM GTP). The assay provides excellent signal at low substrate conversion, with a Z′ = 0.7 and =85 polarization shift (mP) at 10% GTP conversion using 10 μM GTP.
The Transcreener® GDP Assay was developed to follow the progress of any enzyme that produces GDP. The Transcreener® GDP Detection Mixture comprises a GDP Alexa633 Tracer bound to a GDP Antibody. The tracer is displaced by GDP, the invariant product generated during the enzyme reaction. The displaced tracer freely rotates leading to a decrease in fluorescence polarization. Therefore, GDP production is proportional to a decrease in polarization. The assay uses a far red tracer to minimize interference from fluorescent compounds and light scattering.
View full Transcreener® product list
The Transcreener® GDP Assay is a far-red, competitive fluorescence polarization (FP) assay based on the detection of GDP and therefore is compatible with any enzyme that produces GDP, including GTPases such as CDC42. The Transcreener® GDP Assay is a simple one step homogenous detection assay, and is extremely flexible with regard to GTP concentration (1 to 1,000 μM GTP). The assay provides excellent signal at low substrate conversion, with a Z′ = 0.7 and =85 polarization shift (mP) at 10% GTP conversion using 10 μM GTP.
The Transcreener® GDP Assay was developed to follow the progress of any enzyme that produces GDP. The Transcreener® GDP Detection Mixture comprises a GDP Alexa633 Tracer bound to a GDP Antibody. The tracer is displaced by GDP, the invariant product generated during the enzyme reaction. The displaced tracer freely rotates leading to a decrease in fluorescence polarization. Therefore, GDP production is proportional to a decrease in polarization. The assay uses a far red tracer to minimize interference from fluorescent compounds and light scattering.
View full Transcreener® product list
수량
3009-1K = 1,000 assay, 384-well
3009-10K = 10,000 assay, 384-well
3009-10K = 10,000 assay, 384-well
물리적 형태
Kit with buffered aqueous solutions
법적 정보
Transcreener is a registered trademark of BellBrook Labs
시험 성적서(COA)
제품의 로트/배치 번호를 입력하여 시험 성적서(COA)을 검색하십시오. 로트 및 배치 번호는 제품 라벨에 있는 ‘로트’ 또는 ‘배치’라는 용어 뒤에서 찾을 수 있습니다.
자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..
고객지원팀으로 연락바랍니다.