콘텐츠로 건너뛰기
Merck
모든 사진(1)

Key Documents

3020

Sigma-Aldrich

Transcreener® AMP2/GMP2 TR-FRET Assay

동의어(들):

TR-FRET assay, Transcreener assay

로그인조직 및 계약 가격 보기


About This Item

UNSPSC 코드:
41122100
NACRES:
NA.84

배송 상태

dry ice

저장 온도

−20°C

일반 설명

The Transcreener® AMP2/GMP2 TR-FRET Red Assay is a competitive immunoassay for enzymes that produce AMP or GMP with a far-red, time-resolved Förster-resonance-energy-transfer (TR-FRET) readout. The assay relies on a highly specific monoclonal antibody that recognizes AMP or GMP with more than 1,000-fold selectivity over substrate nucleotides, including ATP, cAMP, or cGMP. Enzymes that can be used with the assay include ubiquitin, SUMO, nucleic acid and protein ligases, phosphodiesterases (PDEs), and synthetases. The Transcreener® assay is designed specifically for high-throughput screening (HTS), with a single addition, mix-and-read format. It offers reagent stability and compatibility with commonly used multimode plate readers. The generic nature of the Transcreener® HTS assay platform eliminates delays involved in assay development for new HTS targets and greatly simplifies compound and inhibitor profiling across multiple target families.

The Transcreener® AMP2/GMP2 TR-FRET Red Assay provides the following benefits:
  • Accommodates substrate concentrations ranging from 0.1 μM to 1,000 μM.
  • Excellent data quality (Z′ = 0.7) at low substrate conversion (typically 10–30%).
  • The only assay method that allows detection of unmodified AMP and GMP without using coupling enzymes.
  • Overcomes the need for time-consuming, one-off assay development for individual members within a group transfer enzyme family by using a single set of assay reagents that detect an invariant product.
  • Time-gated detection method largely eliminates interference that can result from prompt fluorescence of test compounds.
  • Far-red tracer further minimizes interference from fluorescent compounds and light scattering.

View full Transcreener® product list

수량

3020-1K = 1,000 assay, 384-well
3020-10K = 10,000 assay, 384-well

물리적 형태

Kit with buffered aqueous solutions

법적 정보

Transcreener is a registered trademark of BellBrook Labs

시험 성적서(COA)

제품의 로트/배치 번호를 입력하여 시험 성적서(COA)을 검색하십시오. 로트 및 배치 번호는 제품 라벨에 있는 ‘로트’ 또는 ‘배치’라는 용어 뒤에서 찾을 수 있습니다.

이 제품을 이미 가지고 계십니까?

문서 라이브러리에서 최근에 구매한 제품에 대한 문서를 찾아보세요.

문서 라이브러리 방문

M Kopani et al.
Bratislavske lekarske listy, 118(10), 575-579 (2017-12-05)
Mobile phone application may cause structural, functional changes and accumulation of toxic elements in brain. The aim of this study was to investigate iron accumulation in rabbit cerebellum after exposure to RF EMF with light and scanning electron microscopy. Histochemical
M J Abramowicz et al.
The Journal of clinical investigation, 99(12), 3018-3024 (1997-06-15)
Thyroid gland agenesis is the most common cause of congenital hypothyroidism and is usually sporadic. We investigated a brother and sister from consanguineous parents, ascertained through systematic newborn screening, and initially diagnosed with thyroid agenesis. Careful cervical ultrasonography in both

자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..

고객지원팀으로 연락바랍니다.