추천 제품
제품명
Hexane, ReagentPlus®, ≥99%
Agency
suitable for EPA 1613
Quality Level
vapor density
~3 (vs air)
vapor pressure
256 mmHg ( 37.7 °C)
5.2 psi ( 37.7 °C)
~132 mmHg ( 20 °C)
제품 라인
ReagentPlus®
분석
≥99%
양식
liquid
autoignition temp.
453 °F
expl. lim.
7.7 %
기술
GC/MS: suitable
refractive index
n20/D 1.375 (lit.)
pH
7
bp
69 °C (lit.)
mp
−95 °C (lit.)
solubility
water: insoluble
density
0.659 g/mL at 25 °C (lit.)
SMILES string
CCCCCC
InChI
1S/C6H14/c1-3-5-6-4-2/h3-6H2,1-2H3
InChI key
VLKZOEOYAKHREP-UHFFFAOYSA-N
유사한 제품을 찾으십니까? 방문 제품 비교 안내
일반 설명
Hexane is an alkane and exists in 5 structural isomeric forms, i.e. hexane, isohexane, 3-methylpentane, neohexane and 2,3-dimethylbutane. It can be obtained from petroleum by distillation. It can also be produced by electrolyzing the potassium butyrate solution. It is widely employed organic solvent for the dissolution and isolation of fats and oils.
애플리케이션
Hexane may be used in the following studies:
Hexane may be used as a solvent in the detection of rubrene, using normal phase high performance liquid chromatography. It may also be used as an extraction solvent to concentrate the analytes like synthetic cannabinoids of the aminoalkylindole type and methanandamide in serum, followed by separation using liquid chromatography coupled with tandem-mass spectrometry.
- Preparation of graft-copolymer chains of poly-(dimethylsiloxane)-g-poly(methyl methacrylate).
- GC/MS (Gas Chromatography/Mass Spectrometry) characterization of essential oils isolated from various origins.
- As solvent for the preparation of samples and standards during chromatographic studies.
Hexane may be used as a solvent in the detection of rubrene, using normal phase high performance liquid chromatography. It may also be used as an extraction solvent to concentrate the analytes like synthetic cannabinoids of the aminoalkylindole type and methanandamide in serum, followed by separation using liquid chromatography coupled with tandem-mass spectrometry.
법적 정보
ReagentPlus is a registered trademark of Merck KGaA, Darmstadt, Germany
적합한 제품을 찾을 수 없으신가요?
당사의 제품 선택기 도구.을(를) 시도해 보세요.
신호어
Danger
유해 및 위험 성명서
Hazard Classifications
Aquatic Chronic 2 - Asp. Tox. 1 - Flam. Liq. 2 - Repr. 2 - Skin Irrit. 2 - STOT RE 2 Inhalation - STOT SE 3
표적 기관
Central nervous system, Nervous system
Storage Class Code
3 - Flammable liquids
WGK
WGK 3
Flash Point (°F)
-7.6 °F - closed cup
Flash Point (°C)
-22 °C - closed cup
이미 열람한 고객
Development and validation of a liquid chromatography?tandem mass spectrometry method for the quantitation of synthetic cannabinoids of the aminoalkylindole type and methanandamide in serum and its application to forensic samples
Journal of Mass Spectrometry : Jms, 46(2), 163-171 (2011)
Occurrence, mechanisms and analytical applications of electrogenerated chemiluminescence. A review
Analyst, 119(5), 879- 890 (1994)
Journal of chromatography. A, 1190(1-2), 120-126 (2008-03-18)
Biodiesel (a mixture of fatty acid esters) is normally analyzed using gas chromatography/flame ionization detection, as specified by the ASTM D6584 and EN14105 standards. This paper proposes a binary gradient method for analyzing biodiesel mixtures using non-aqueous reverse phase HPLC
Comparative evaluation of 11 essential oils of different origin as functional antioxidants, antiradicals and antimicrobials in foods.
Food Chemistry, 91(4), 621-632 (2005)
Langmuir : the ACS journal of surfaces and colloids, 21(12), 5298-5306 (2005-06-01)