추천 제품
grade
puriss.
Quality Level
분석
98-102.5%
형태
powder
품질
meets analytical specification of Ph. Eur., BP, USP
불순물
organic volatile impurities, complies
residual solvents, complies
≤0.003% heavy metals (as Pb)
≤0.1% insoluble in HCl
손실
24.5-26.5% loss on ignition, 800 °C
음이온 미량물
carbonate (CO32-): in accordance
chloride (Cl-): ≤200 mg/kg
fluoride (F-): ≤50 mg/kg
sulfate (SO42-): ≤3000 mg/kg
양이온 미량물
As: ≤1 mg/kg
Ba:, in accordance (Ph Eur)
Ba:, in accordance (USP)
Fe: ≤300 mg/kg
SMILES string
O.O.[Ca++].OP([O-])([O-])=O
InChI
1S/Ca.H3O4P.2H2O/c;1-5(2,3)4;;/h;(H3,1,2,3,4);2*1H2/q+2;;;/p-2
InChI key
XAAHAAMILDNBPS-UHFFFAOYSA-L
유사한 제품을 찾으십니까? 방문 제품 비교 안내
애플리케이션
- Simultaneous Regulation of the Mechanical/Osteogenic Capacity of Brushite Calcium Phosphate Cement by Incorporating with Poly(ethylene glycol) Dicarboxylic Acid: This research investigates enhancing brushite calcium phosphate cements by adding poly(ethylene glycol) dicarboxylic acid to improve mechanical properties and osteogenic capabilities, applicable in bone regeneration and implant materials. (Gao et al., 2024).
- Biosurfactant-Assisted Cu Doping of Brushite Coatings: Explores the structural and biofunctional enhancements of brushite coatings through copper doping facilitated by biosurfactants, which could revolutionize surface treatments for biocompatible implants and devices. (Siva Prasad et al., 2024).
- Self-Healing Micro Arc Oxidation and Dicalcium Phosphate Dihydrate Double-Passivated Coating on Magnesium Membrane for Enhanced Bone Integration Repair: This study highlights the application of calcium phosphate dibasic dihydrate in developing protective coatings on magnesium-based implants, significantly advancing orthopedic and dental implant technologies. (Wu et al., 2024).
- Physiologically Engineered Porous Titanium/Brushite Scaffolds for Critical-Size Bone Defects: Details the design and fabrication of novel scaffolds for treating large bone defects, utilizing a combination of titanium and brushite, highlighting its potential in reconstructive surgery and regenerative medicine. (Abdulaziz et al., 2023).
- Mechanochemical Synthesis of Cerium Chlorapatite from a Mixture of Cerium Chloride Heptahydrate, Dicalcium Phosphate Dihydrate, and Calcium Hydroxide for Biomedical Application: Focuses on the innovative production of cerium chlorapatite using dicalcium phosphate dihydrate, showcasing its potential in biomedical engineering, especially in drug delivery and tissue engineering. (Otsuka et al., 2024).
신호어
Warning
유해 및 위험 성명서
Hazard Classifications
Eye Irrit. 2 - Skin Irrit. 2 - STOT SE 3
표적 기관
Respiratory system
Storage Class Code
11 - Combustible Solids
WGK
WGK 1
Flash Point (°F)
Not applicable
Flash Point (°C)
Not applicable
시험 성적서(COA)
제품의 로트/배치 번호를 입력하여 시험 성적서(COA)을 검색하십시오. 로트 및 배치 번호는 제품 라벨에 있는 ‘로트’ 또는 ‘배치’라는 용어 뒤에서 찾을 수 있습니다.
자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..
고객지원팀으로 연락바랍니다.