92332
Chloride ionophore IV
Selectophore™, for ion-selective electrodes
동의어(들):
4,5-Bis-[N′-(butyl)thioureido]-2,7-di-tert-butyl-9,9-dimethylxanthene
로그인조직 및 계약 가격 보기
모든 사진(2)
About This Item
실험식(Hill 표기법):
C33H50N4OS2
CAS Number:
Molecular Weight:
582.91
MDL number:
UNSPSC 코드:
26111700
PubChem Substance ID:
NACRES:
NB.61
추천 제품
Grade
for ion-selective electrodes
Quality Level
제품 라인
Selectophore™
양식
powder
SMILES string
CCCCNC(=S)Nc1cc(cc2c1Oc3c(NC(=S)NCCCC)cc(cc3C2(C)C)C(C)(C)C)C(C)(C)C
InChI
1S/C33H50N4OS2/c1-11-13-15-34-29(39)36-25-19-21(31(3,4)5)17-23-27(25)38-28-24(33(23,9)10)18-22(32(6,7)8)20-26(28)37-30(40)35-16-14-12-2/h17-20H,11-16H2,1-10H3,(H2,34,36,39)(H2,35,37,40)
InChI key
GYGZJHGSLBVTPV-UHFFFAOYSA-N
일반 설명
Visit our Sensor Applications portal to learn more.
애플리케이션
Selected application examples
법적 정보
Selectophore is a trademark of Merck KGaA, Darmstadt, Germany
관련 제품
제품 번호
설명
가격
Storage Class Code
11 - Combustible Solids
WGK
WGK 3
Flash Point (°F)
Not applicable
Flash Point (°C)
Not applicable
개인 보호 장비
Eyeshields, Gloves, type N95 (US)
이미 열람한 고객
Wenjun Di et al.
Analytical methods : advancing methods and applications, 12(11), 1441-1448 (2020-04-01)
Personalized approaches for continuous monitoring of chloride levels are potentially valuable for evaluating the efficacy of new treatments of genetic disorders such as cystic fibrosis. In this report, we validated optode-based nanosensors for real-time chloride monitoring in the interstitial fluid
Chloride ionophore, detection limit ~0.0000065 M chloride. Detection of chloride in biological samples.
K.P. Xiao et al.
Analytical Chemistry, 69, 1038-1038 (1997)
Strong Hydrogen Bond-Mediated Complexation of H2PO4- by Neutral Bis-Thiourea Hosts
P. Buhlmann et al.
Tetrahedron, 53, 1647-1647 (1997)
Antra Ganguly et al.
Sensors (Basel, Switzerland), 19(20) (2019-10-28)
This work demonstrates a novel electrochemical biosensor for the detection of chloride ion levels in ultra-low volumes (1-3 microliters) of passively expressed human sweat. We present here a hydration monitor that the pediatric, geriatric, and other immune-compromised or physically inactive/sedentary
Antra Ganguly et al.
SLAS technology, 25(1), 25-32 (2019-10-17)
Misclassification of an acute disease condition as chronic and vice versa by electrochemical sweat biomarker sensors can cause significant psychological, emotional, and financial stress among patients. To achieve higher accuracy in distinguishing between a chronic condition and an acute condition
자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..
고객지원팀으로 연락바랍니다.