콘텐츠로 건너뛰기
Merck
모든 사진(2)

Key Documents

92332

Supelco

Chloride ionophore IV

Selectophore

동의어(들):

4,5-Bis-[N′-(butyl)thioureido]-2,7-di-tert-butyl-9,9-dimethylxanthene

로그인조직 및 계약 가격 보기


About This Item

실험식(Hill 표기법):
C33H50N4OS2
CAS Number:
Molecular Weight:
582.91
MDL number:
UNSPSC 코드:
26111700
PubChem Substance ID:
NACRES:
NB.61

Grade

for ion-selective electrodes

Quality Level

제품 라인

Selectophore

형태

powder

SMILES string

CCCCNC(=S)Nc1cc(cc2c1Oc3c(NC(=S)NCCCC)cc(cc3C2(C)C)C(C)(C)C)C(C)(C)C

InChI

1S/C33H50N4OS2/c1-11-13-15-34-29(39)36-25-19-21(31(3,4)5)17-23-27(25)38-28-24(33(23,9)10)18-22(32(6,7)8)20-26(28)37-30(40)35-16-14-12-2/h17-20H,11-16H2,1-10H3,(H2,34,36,39)(H2,35,37,40)

InChI key

GYGZJHGSLBVTPV-UHFFFAOYSA-N

일반 설명

Visit our Sensor Applications portal to learn more.

애플리케이션

Selected application examples

법적 정보

Selectophore is a trademark of Merck KGaA, Darmstadt, Germany

Storage Class Code

11 - Combustible Solids

WGK

WGK 3

Flash Point (°F)

Not applicable

Flash Point (°C)

Not applicable

개인 보호 장비

Eyeshields, Gloves, type N95 (US)


가장 최신 버전 중 하나를 선택하세요:

시험 성적서(COA)

Lot/Batch Number

적합한 버전을 찾을 수 없으신가요?

특정 버전이 필요한 경우 로트 번호나 배치 번호로 특정 인증서를 찾을 수 있습니다.

이 제품을 이미 가지고 계십니까?

문서 라이브러리에서 최근에 구매한 제품에 대한 문서를 찾아보세요.

문서 라이브러리 방문

이미 열람한 고객

Wenjun Di et al.
Analytical methods : advancing methods and applications, 12(11), 1441-1448 (2020-04-01)
Personalized approaches for continuous monitoring of chloride levels are potentially valuable for evaluating the efficacy of new treatments of genetic disorders such as cystic fibrosis. In this report, we validated optode-based nanosensors for real-time chloride monitoring in the interstitial fluid
Chloride ionophore, detection limit ~0.0000065 M chloride. Detection of chloride in biological samples.
K.P. Xiao et al.
Analytical Chemistry, 69, 1038-1038 (1997)
Strong Hydrogen Bond-Mediated Complexation of H2PO4- by Neutral Bis-Thiourea Hosts
P. Buhlmann et al.
Tetrahedron, 53, 1647-1647 (1997)
Antra Ganguly et al.
Sensors (Basel, Switzerland), 19(20) (2019-10-28)
This work demonstrates a novel electrochemical biosensor for the detection of chloride ion levels in ultra-low volumes (1-3 microliters) of passively expressed human sweat. We present here a hydration monitor that the pediatric, geriatric, and other immune-compromised or physically inactive/sedentary
Antra Ganguly et al.
SLAS technology, 25(1), 25-32 (2019-10-17)
Misclassification of an acute disease condition as chronic and vice versa by electrochemical sweat biomarker sensors can cause significant psychological, emotional, and financial stress among patients. To achieve higher accuracy in distinguishing between a chronic condition and an acute condition

자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..