콘텐츠로 건너뛰기
Merck
모든 사진(1)

Key Documents

81503

Supelco

Poly(methyl methacrylate)

analytical standard, for GPC, 100,000

동의어(들):

PMMA, Poly(methacrylic acid methyl ester)

로그인조직 및 계약 가격 보기


About This Item

Linear Formula:
[CH2C(CH3)(CO2CH3)]n
CAS Number:
MDL number:
UNSPSC 코드:
41116107
PubChem Substance ID:
NACRES:
NA.24

Grade

analytical standard
for GPC

Quality Level

autoignition temp.

580 °F

유통기한

limited shelf life, expiry date on the label

분자량

Mn ~91500
Mp ~102500
Mw ~98500

기술

gel permeation chromatography (GPC): suitable

solubility

H2O: insoluble

density

1.200 g/cm3

Mw/Mn

~1.08

형식

neat

저장 온도

2-8°C

InChI

1S/C5H9O2/c1-4(2)5(6)7-3/h1-3H3

InChI key

PMAMJWJDBDSDHV-UHFFFAOYSA-N

유사한 제품을 찾으십니까? 방문 제품 비교 안내

애플리케이션

Poly(methyl methacrylate) may be used as a reference suspension polymer for the analysis of the composition of poly(methyl methacrylate) (PMMA) by gas chromatography method.

Storage Class Code

11 - Combustible Solids

WGK

nwg

개인 보호 장비

Eyeshields, Gloves, type N95 (US)


가장 최신 버전 중 하나를 선택하세요:

시험 성적서(COA)

Lot/Batch Number

적합한 버전을 찾을 수 없으신가요?

특정 버전이 필요한 경우 로트 번호나 배치 번호로 특정 인증서를 찾을 수 있습니다.

이 제품을 이미 가지고 계십니까?

문서 라이브러리에서 최근에 구매한 제품에 대한 문서를 찾아보세요.

문서 라이브러리 방문

Analysis of pyrolyzates of polystyrene and poly (methyl methacrylate) by gas chromatography.
Lehmann FA and Brauer GM
Analytical Chemistry, 33(6), 673-676 (1961)
Pleural infection 55 years after plombage for pulmonary tuberculosis.
Qian-kun Chen et al.
Asian cardiovascular & thoracic annals, 21(1), 100-100 (2013-02-23)
Lucía D Garza-García et al.
Lab on a chip, 13(7), 1243-1246 (2013-02-16)
We report a proof-of-principle for the use of micro-devices as continuous bioreactors for the production of monoclonal antibodies. We culture CHO cells on the surface of PMMA "zigzag" channels textured with semi-spherical cavities coated with fibronectin, observing steady-state productivities 100
Gursukhman S Sidhu et al.
Journal of neurosurgery. Spine, 19(1), 61-70 (2013-05-07)
The authors endeavor to highlight the surgical management of severe neurological deficit resulting from cement leakage after percutaneous vertebroplasty and to systematically review the literature on the management of this complication. A patient presented after a vertebroplasty procedure for traumatic
S A Bini et al.
The bone & joint journal, 95-B(3), 367-370 (2013-03-02)
We evaluated the impact of pre-coating the tibial component with polymethylmethacrylate (PMMA) on implant survival in a cohort of 16 548 primary NexGen total knee replacements (TKRs) in 14 113 patients. In 13 835 TKRs a pre-coated tray was used

자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..

고객지원팀으로 연락바랍니다.