콘텐츠로 건너뛰기
Merck
모든 사진(3)

주요 문서

445746

Sigma-Aldrich

Poly(methyl methacrylate)

average Mw ~350,000 by GPC

동의어(들):

PMMA, Poly(methacrylic acid methyl ester)

로그인조직 및 계약 가격 보기


About This Item

Linear Formula:
[CH2C(CH3)(CO2CH3)]n
CAS Number:
MDL number:
UNSPSC 코드:
12162002
PubChem Substance ID:
NACRES:
NA.23

양식

powder

Quality Level

autoignition temp.

580 °F

분자량

average Mw ~350,000 by GPC

환원 점도

150-160 cm3/g(20 °C)(lit.)

산성 번호

<1 mg KOH/g

전이 온도

Tg (DSC) 105 °C (midpoint)

solubility

alcohols and aliphatic hydrocarbons: insoluble
esters, ketones, aromatics and glycol ethers: soluble

density

1.17 g/mL at 25 °C

InChI

1S/C5H9O2/c1-4(2)5(6)7-3/h1-3H3

InChI key

PMAMJWJDBDSDHV-UHFFFAOYSA-N

유사한 제품을 찾으십니까? 방문 제품 비교 안내

일반 설명

The thermal degradation behaviour of PMMA ( avg Mol. wt. ~350,000 g mol-1)was investigated in inert atmosphere, four weight loss steps were observed.

애플리케이션

PMMA (avg. Mol wt. ~350,000 g mol-1) containing Fe2O3 and TiO2 fillers have possible uses as flame retardants.
Pigment-wetting binder for coatings.

특징 및 장점

Contributes hardness, weather resistance, light fastness and resistance to chemicals.

Storage Class Code

11 - Combustible Solids

WGK

nwg

개인 보호 장비

Eyeshields, Gloves, type N95 (US)


가장 최신 버전 중 하나를 선택하세요:

시험 성적서(COA)

Lot/Batch Number

적합한 버전을 찾을 수 없으신가요?

특정 버전이 필요한 경우 로트 번호나 배치 번호로 특정 인증서를 찾을 수 있습니다.

이 제품을 이미 가지고 계십니까?

문서 라이브러리에서 최근에 구매한 제품에 대한 문서를 찾아보세요.

문서 라이브러리 방문

Influence of TiO2 and Fe2O3 fillers on the thermal properties of poly (methyl methacrylate)(PMMA).
Laachachi A.,et al.
Material Matters, 59(1), 36-39 (2005)
Thermal degradation of poly (methyl methacrylate)(PMMA): modelling of DTG and TG curves.
Ferriol M., et al.
Polymer Degradation and Stability, 79(2), 271-281 (2003)
Pleural infection 55 years after plombage for pulmonary tuberculosis.
Qian-kun Chen et al.
Asian cardiovascular & thoracic annals, 21(1), 100-100 (2013-02-23)
Gursukhman S Sidhu et al.
Journal of neurosurgery. Spine, 19(1), 61-70 (2013-05-07)
The authors endeavor to highlight the surgical management of severe neurological deficit resulting from cement leakage after percutaneous vertebroplasty and to systematically review the literature on the management of this complication. A patient presented after a vertebroplasty procedure for traumatic
S A Bini et al.
The bone & joint journal, 95-B(3), 367-370 (2013-03-02)
We evaluated the impact of pre-coating the tibial component with polymethylmethacrylate (PMMA) on implant survival in a cohort of 16 548 primary NexGen total knee replacements (TKRs) in 14 113 patients. In 13 835 TKRs a pre-coated tray was used

문서

Professor Aran (Claremont University, USA) thoroughly discusses the engineering of graphene based materials through careful functionalization of graphene oxide, a solution processable form of graphene.

Developed in the last several years, fluorescence quenching microscopy (FQM) has enabled rapid, inexpensive, and high-fidelity visualization of two-dimensional (2D) materials such as graphene-based sheets and MoS2.

We will explore the technological advances that have contributed toward the progress of 3DP of tissue engineering scaffolds, current materials used to create 3DP scaffolds, and the challenges that remain.

모두 보기

자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..

고객지원팀으로 연락바랍니다.