Agency
AOAC® (PTM)
Quality Level
유통기한
6‑12 mo.
포장
pkg of 52 tests
제조업체/상표
Assurance GDS®
BioControl Systems 71019-52
기술
PCR: suitable
응용 분야
food and beverages
pathogen testing
호환성
for use with GDS Rotor-Gene
저장 온도
2-8°C
적합성
enterovirulent E. coli (EEC) (shiga toxigenic)
일반 설명
Assurance® GDS is an advanced genetic detection system for food pathogens. The MPX ID for Top STEC is a secondary automated nucleic acid amplification system for the identification of “Top Six” non-O157 Shiga Toxigenic E. coli (STEC). The Top 6 non-O157 STEC are defined as E. coli belonging to serogroups O103, O111, O121, O145, O26, or O45 that possess both the eae gene and at least one of the Shiga Toxin genes (stx1 or stx2). GDS MPX ID utilizes a proprietary PickPen® IMS-based sample preparation procedure to quickly and effectively capture organisms belonging to the 6 specific Top STEC O-serogroups prior to genetic analysis for the associated pathogenicity genes. Each of the 3 unique eae gene sequences targeted by MPX ID are highly correlated plus one or more of the 6 O-serogroups comprising Top 6 non-O157 STEC. Because there are 3 different eae gene targets and 6 different O-serogroup targets, the PCR reactions have been divided between 2 Amplification Tubes. Each tube contains an internal control and all necessary PCR reagents. Results will automatically be combined between the 2 tubes via GDS Rotor-Gene® software.
애플리케이션
Assurance® GDS MPX ID for Top STEC is designed to follow GDS MPX Top 7 STEC (PN 71015BC) for the identification of “Top Six” non-O157 Shiga Toxigenic E. coli (STEC) in a variety of foods, ingredients, and environmental samples. Additionally, GDS MPX ID can be used to confirm isolated colonies from samples presumptive positive for Top 6 STEC.
특징 및 장점
- Designed specifically to follow GDS MPX Top STEC assays
- Identification of the specific O serogroup(s) responsible for the positive STEC result and verifies that all targets relevant to the definition of a Top 6 STEC (eae, stx and O group) are present within a single organism
- Confirm isolated colonies from samples presumptive positive for Top 6 STEC
- Utilizes the same single-step mEHEC® enrichment media common to all BioControl methods for Salmonella, E.coli O157:H7, Shiga Toxin genes, and Top STEC
- Only 14 hours from start to finish
성분
- MPX Group 1 STEC Amplification Tubes
- MPX Group 2 STEC Amplification Tubes
- Top 6 STEC Concentration Reagent
- Resuspension Buffer Tq
- Top STEC Wash Solution
호환성
BioControl GDS
검사법
PCR, Immunomagnetic Separation (IMS)
법적 정보
AOAC is a registered trademark of AOAC International
Assurance is a registered trademark of Merck KGaA, Darmstadt, Germany
Assurance GDS is a registered trademark of BioControl Systems, Inc.
PICKPEN is a registered trademark of Merck KGaA, Darmstadt, Germany
Rotor-Gene is a registered trademark of Qiagen GmbH
mEHEC is a registered trademark of Merck KGaA, Darmstadt, Germany
설정됨
제품 번호
설명
가격
필요하나 제공되지 않음
제품 번호
설명
가격
신호어
Warning
유해 및 위험 성명서
예방조치 성명서
Hazard Classifications
Met. Corr. 1
Storage Class Code
8A - Combustible, corrosive hazardous materials
WGK
WGK 3
Choose from one of the most recent versions:
이미 열람한 고객
자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..
고객지원팀으로 연락바랍니다.