추천 제품
Grade
analytical standard
Quality Level
유통기한
limited shelf life, expiry date on the label
기술
HPLC: suitable
gas chromatography (GC): suitable
mp
276-279 °C (lit.)
응용 분야
environmental
형식
neat
SMILES string
c1cc2cccc3c4cccc5cccc(c(c1)c23)c45
InChI
1S/C20H12/c1-5-13-6-2-11-17-18-12-4-8-14-7-3-10-16(20(14)18)15(9-1)19(13)17/h1-12H
InChI key
CSHWQDPOILHKBI-UHFFFAOYSA-N
유사한 제품을 찾으십니까? 방문 제품 비교 안내
일반 설명
Perylene belongs to the class of polycyclic aromatic hydrocarbons. It is a hydrophobic fluorescent probe used for imaging lipid bilayer membranes.
애플리케이션
Perylene may be used as an analytical standard along with a mixture of polycyclic aromatic hydrocarbons (PAHs) to determine the spatial distribution and sources of PAHs in surface sediments of rivers. It may also be used as an analytical reference standard for the quantification of the analyte in water samples using spectrofluorimetric technique.
Refer to the product′s Certificate of Analysis for more information on a suitable instrument technique. Contact Technical Service for further support.
Storage Class Code
11 - Combustible Solids
WGK
WGK 3
Flash Point (°F)
Not applicable
Flash Point (°C)
Not applicable
개인 보호 장비
Eyeshields, Gloves, type N95 (US)
가장 최신 버전 중 하나를 선택하세요:
이미 열람한 고객
Fluorescence probe partitioning between Lo/Ld phases in lipid membranes
Biochimica et Biophysica Acta - Biomembranes, 1768(9), 2182-2194 (2007)
Simultaneous synchronous flourimetric determination of benzo [a] pyrene and perylene in micellar media
Analytica Chimica Acta, 255(1), 107-111 (1991)
Distribution and sources of polycyclic aromatic hydrocarbons in surface sediments of rivers and an estuary in Shanghai, China
Environmental Pollution (Barking, Essex : 1987), 154(2), 298-305 (2008)
The journal of physical chemistry. B, 117(9), 2742-2747 (2013-02-07)
Herein, we report on the theoretical-experimental analysis of the two-photon absorption (TPA) and two-photon circular-linear dichroism (TPCLD) spectra of a highly conjugated, rigid, and centrosymmetric molecule in solution, that is, perylene/CH2Cl2. We show how a three-energy-level diagram, under the sum-over-essential
Chemical communications (Cambridge, England), 49(21), 2139-2141 (2013-02-08)
Novel pH sensors relying on 1-aminoperylene bisimide dyes covalently grafted onto cross-linked poly(acryloylmorpholine) are presented. They feature fluorescence in the near infra-red range and a large Stokes shift (>90 nm).
프로토콜
GC Analysis of Polynuclear Aromatic Hydrocarbons (PAHs) in Salmon on SPB®-608 (20 m x 0.18 mm I.D., 0.18 µm) after QuEChERS Cleanup using Supel™ QuE Z-Sep, Fast GC Analysis
자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..
고객지원팀으로 연락바랍니다.