추천 제품
Grade
analytical standard
유통기한
limited shelf life, expiry date on the label
농도
50 μg/mL in isooctane
기술
HPLC: suitable
gas chromatography (GC): suitable
응용 분야
environmental
형식
single component solution
저장 온도
2-8°C
SMILES string
Brc1cc(Br)c(Oc2c(Br)cc(Br)c(Br)c2Br)cc1Br
InChI
1S/C12H3Br7O/c13-4-1-6(15)9(3-5(4)14)20-12-8(17)2-7(16)10(18)11(12)19/h1-3H
InChI key
ILPSCQCLBHQUEM-UHFFFAOYSA-N
일반 설명
BDE No 183 belongs to the class of polybrominated diphenyl ethers. It can be commercially used as a flame retardant additive in building materials, textiles, plastics and electronic equipment.
애플리케이션
BDE No 183 may be used as an analytical reference standard for the determination of the analyte in house dust using liquid chromatography with negative-ion atmospheric pressure photoionization tandem mass spectrometry (LC/NI-APPI/MS/MS).
Refer to the product′s Certificate of Analysis for more information on a suitable instrument technique. Contact Technical Service for further support.
기타 정보
The customer needs to make sure that the standard is homogeneous, this can be achieved by shaking, vortexing , or sonicating the ampoule before opening the ampoule. Care should be taken when opening the ampoule to avoid any injuries from the broken glass.
The standard should be transferred to a clean and appropriate vial or flask using clean pipettes or micro pipettes. The vial should be immediately capped to avoid any loss or evaporation of the solvent.
After opening the ampoule, the standard should not be stored or kept in the ampoule. To preserve the integrity of the product, the standard should be transferred to an appropriate vial that must be capped and stored according to the recommendation on the Certificate of Analysis.
The standard should be transferred to a clean and appropriate vial or flask using clean pipettes or micro pipettes. The vial should be immediately capped to avoid any loss or evaporation of the solvent.
After opening the ampoule, the standard should not be stored or kept in the ampoule. To preserve the integrity of the product, the standard should be transferred to an appropriate vial that must be capped and stored according to the recommendation on the Certificate of Analysis.
신호어
Danger
유해 및 위험 성명서
Hazard Classifications
Aquatic Acute 1 - Aquatic Chronic 1 - Asp. Tox. 1 - Flam. Liq. 2 - Skin Irrit. 2 - STOT SE 3
표적 기관
Central nervous system
Storage Class Code
3 - Flammable liquids
WGK
WGK 2
Flash Point (°F)
10.4 °F
Flash Point (°C)
-12 °C
개인 보호 장비
Eyeshields, Faceshields, Gloves, type ABEK (EN14387) respirator filter
Analysis of polybrominated diphenyl ethers (PBDEs) by liquid chromatography with negative-ion atmospheric pressure photoionization tandem mass spectrometry (LC/NI-APPI/MS/MS): application to house dust
Analytical and Bioanalytical Chemistry, 391(6), 2249-2256 (2008)
Journal of medicinal chemistry, 49(25), 7366-7372 (2006-12-08)
To investigate androgen receptor (AR) activation by exogenous compounds, we used a combination of experimental analysis and theoretical modeling to compare a set of brominated flame retardants (BFRs) to dihydrotestosterone (DHT) with regard to ligand docking, AR binding, and AR
자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..
고객지원팀으로 연락바랍니다.