추천 제품
Grade
for ion-selective electrodes
Quality Level
제품 라인
Selectophore™
품질
function tested
mp
50-53 °C
SMILES string
CCCCCCCCCCCCCCCCCCN(CCCCCCCCCCCCCCCCCC)C(=O)COCC(=O)N(C1CCCCC1)C2CCCCC2
InChI
1S/C52H100N2O3/c1-3-5-7-9-11-13-15-17-19-21-23-25-27-29-31-39-45-53(46-40-32-30-28-26-24-22-20-18-16-14-12-10-8-6-4-2)51(55)47-57-48-52(56)54(49-41-35-33-36-42-49)50-43-37-34-38-44-50/h49-50H,3-48H2,1-2H3
InChI key
CLLKVTAGSOWKHA-UHFFFAOYSA-N
유사한 제품을 찾으십니까? 방문 제품 비교 안내
일반 설명
Visit our Sensor Applications portal to learn more.
애플리케이션
Selected application examples
Calcium ionophore IV (ETH 5234) was used in preparing membrane for the pseudoreference electrode in tetrahydrofuran, in a study to demonstrate electrochemical sample matrix elimination for trace level potentiometric detection.
Calcium ionophore IV may be used in the preparation of Ca2+-selective membrane utilizing AlGaN/GaN transistors for potentiometric calcium ion detection.
포장
Bottomless glass bottle. Contents are inside inserted fused cone.
기타 정보
Extremely lipophilic Ca2+-selective ionophore for chemical sensors of long lifetime; it induces selectivities for Ca over Mg, Na and K of 104, 106, and 108, respectively.
법적 정보
Selectophore is a trademark of Merck KGaA, Darmstadt, Germany
관련 제품
제품 번호
설명
가격
Storage Class Code
11 - Combustible Solids
WGK
WGK 3
Flash Point (°F)
Not applicable
Flash Point (°C)
Not applicable
개인 보호 장비
Eyeshields, Gloves, type N95 (US)
가장 최신 버전 중 하나를 선택하세요:
이미 열람한 고객
Lowering the Detection Limit of Solvent Polymeric Ion-Selective Membrane Electrodes. 2. Influence of Composition of Sample and Internal Electrolyte Solution
Analytical Chemistry, 71(6), 1210-1214 (1999)
Analytical chemistry, 82(1), 436-440 (2009-12-04)
A novel magnesium-selective ion-channel mimetic sensor based on a well-known calcium ionophore, ETH 5234, was demonstrated. Due to different stoichiometry of the ionophore with Mg(2+) and Ca(2+), the sensor exhibits high selectivity to Mg(2+) by controlling ionophore concentration on the
Analytica chimica acta, 987, 105-110 (2017-09-17)
We demonstrate highly selective and sensitive potentiometric ion sensors for calcium ion detection, operated without the use of a reference electrode. The sensors consist of AlGaN/GaN heterostructure-based transistor devices with chemical functionalisation of the gate area using poly (vinylchloride)-based (PVC)
Analytical chemistry, 80(15), 6114-6118 (2008-06-24)
Potentiometric sensors are today sufficiently well understood and optimized to reach ultratrace level (subnanomolar) detection limits for numerous ions. In many cases of practical relevance, however, a high electrolyte background hampers the attainable detection limits. A particularly difficult sample matrix
Chimia, 43, 377-377 (1989)
자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..
고객지원팀으로 연락바랍니다.