추천 제품
형태
beads
autoignition temp.
800 °F
기술
LPLC: suitable
표면적
750 m2/g
손실
~55% loss on drying, 110 °C
기질
styrene-divinylbenzene
기질 활성군
polymer
입자 크기
20-60 mesh
공극 크기
~0.98 mL/g pore volume
100 Å mean pore size
density
1.02 g/mL (true wet)(lit.)
1.08 g/mL (skeletal)(lit.)
분리 기술
reversed phase
유사한 제품을 찾으십니까? 방문 제품 비교 안내
일반 설명
Nonionic macroreticular resin that adsorbs and releases ionic species through hydrophobic and polar interactions; usually used under isocratic conditions.
애플리케이션
Amberlite XAD-4 has been used in the clean-up procedure prior to high performance liquid chromatography-evaporative laser scattering detector (HPLC-ELSD) analysis of mycotoxin fumonisins in corn products. It has also been used as a solid sorbent to trap imidacloprid and its metabolite 6-chloronicotinic acid from greenhouse air prior to their determination by HPLC coupled to diode array detector (DAD).
Polyaromatic adsorbent for small hydrophobic compounds, surfactants, pharmaceutical manufacturing, phenols, chlorinated organics, pesticide removal and recovery, and organic removal from aqueous food streams.
기타 정보
Two particle sizes are available:
Mesh 20-60 are Cat. Nos. 20276, 10358, XAD4
Mesh 20-50 is Cat. No. 06444
Mesh 20-60 are Cat. Nos. 20276, 10358, XAD4
Mesh 20-50 is Cat. No. 06444
법적 정보
Amberlite is a trademark of DuPont de Nemours, Inc.
Storage Class Code
11 - Combustible Solids
WGK
WGK 3
Flash Point (°F)
Not applicable
Flash Point (°C)
Not applicable
개인 보호 장비
Eyeshields, Gloves, type N95 (US)
Choose from one of the most recent versions:
Analysis of mycotoxin fumonisins in corn products by high-performance liquid chromatography coupled with evaporative light scattering detection.
Food Chemistry, 107(2), 970-976 (2008)
Bioresource technology, 102(17), 8035-8039 (2011-07-09)
The present work proposes the use of Pleurotus ostreatus immobilized on Amberlite XAD-4 as new biosorbent in trace metal determination. The effects of experimental parameters, such as "pH and flow rate of sample solution, amount of solid phase, eluent type
Ecotoxicology and environmental safety, 73(7), 1620-1628 (2010-08-06)
The tannery effluents at Kanpur (India) have been in use for irrigation since last many years, polluting soil directly while ground water and food crops indirectly. Gas chromatography-mass spectrometric analysis of the test samples revealed the presence of organic compounds
Environmental monitoring and assessment, 185(3), 2691-2704 (2012-07-20)
Nascent Amberlite XAD-4 has been used as the polymeric support for the synthesis of a stable extractor of metal ions, by incorporating phthalic acid through azo bridging. Elemental analyses and infra-red spectral and thermal studies were carried out for its
Journal of hazardous materials, 171(1-3), 815-819 (2009-07-18)
Fluoride in drinking water above permissible level is responsible for human being affected by skeletal fluorosis. In this study, Amberlite XAD-4 has been modified by introducing amino group onto the aromatic ring for its application in fluoride remediation. Characterization of
자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..
고객지원팀으로 연락바랍니다.