콘텐츠로 건너뛰기
Merck
모든 사진(4)

주요 문서

SCT272

Sigma-Aldrich

BioTracker Red Mitochondria Live Cell Probe 400 μL

Human

동의어(들):

mitochondria dye, mitochondria live cell dye, mitochondria probe, mitochondrial live cell dye, red mitochondria dye, red mitochondria probe

로그인조직 및 계약 가격 보기


About This Item

UNSPSC 코드:
41106514
NACRES:
NA.47

product name

BioTracker Red Mitochondria Live Cell Probe 400 μL,

생물학적 소스

human

Quality Level

포장

vial of 400 μL

제조업체/상표

Millipore

기술

cell culture | stem cell: suitable
flow cytometry: suitable

배송 상태

2-8°C

저장 온도

2-8°C

일반 설명

The BioTracker Mitochondria Live Cell Probe demonstrates excellent intracellular retention, enabling long-term staining of mitochondria for up to five days.This easy-to-use live cell probe:*demonstrates high intracellular retention*enables long-term visualization of mitochondria*is provided as ready-to-use DMSO solution*can be used with collagen-coated plates

특징 및 장점

The SCT272 live cell probe is designed to exhibit mitochondrial retention to enable long-term visualization of mitochondria.

표적 설명

The mitochondrion is a multifunctional organelle involved in energy production for the cell plus additional cellular functions. The active cycle of mitochondrial fusion and division induces morphological changes, called mitochondrial dynamics. Abnormalities in morphological dynamics are associated with neurodegenerative diseases, metabolic disorders, and other disorders. The demand for tools enabling long-term observation of mitochondrial dynamics has therefore increased.Methods for monitoring mitochondrial dynamics are usually based on small fluorescent molecules or plasmid transfection techniques. The use of plasmids requires the target protein to be stably expressed, while small fluorescent molecules are widely used because they can simply be added to cells. Among commercially available small fluorescent molecules, those containing the chloromethyl moiety are common. However, these dyes have limitations, including short-term retention in cells, decreased fluorescence intensity in serum, and high background.The BioTracker Red Mitochondria Live Cell Probe overcomes these limitations. This probe is designed to exhibit mitochondrial fluorescence retention for long-term visualization. In addition, SCT272 shows stronger fluorescent signal compared with other commercially available dyes that contain the chloromethyl moiety.

저장 및 안정성

Store BioTracker Red Mitochondria Live Cell Probe at -20 °C, protected from light.

기타 정보

SCT272 is provided as a ready-to-use DMSO solution. A working solution can easily be prepared in a single dilution step with growth medium or HBSS.

법적 정보

BioTracker is a trademark of Merck KGaA, Darmstadt, Germany

면책조항

Unless otherwise stated in our catalog or other company documentation accompanying the product(s), our products are intended for research use only and are not to be used for any other purpose, which includes but is not limited to, unauthorized commercial uses, in vitro diagnostic uses, ex vivo or in vivo therapeutic uses or any type of consumption or application to humans or animals.

Storage Class Code

10 - Combustible liquids

WGK

WGK 1

Flash Point (°F)

188.6 °F - closed cup

Flash Point (°C)

87 °C - closed cup