콘텐츠로 건너뛰기
Merck
모든 사진(1)

Key Documents

PRCYT2MAG40K

Millipore

MILLIPLEX® Non-Human Primate Cytokine/Chemokine Panel II - Immunology Multiplex Assay

Simultaneously analyze multiple cytokine and chemokine biomarkers with Bead-Based Multiplex Assays using the Luminex technology, in non-human primate serum, plasma and cell culture samples.

로그인조직 및 계약 가격 보기


About This Item

UNSPSC 코드:
12161503
eCl@ss:
32161000
NACRES:
NA.47

Quality Level

종 반응성

nonhuman primates

제조업체/상표

Milliplex®

assay range

accuracy: 80-109%
(Overnight Incubation)

standard curve range: 1-1,500 pg/mL
(IL-17A)

standard curve range: 1-750 pg/mL
(RANTES/CCL5 (tissue culture))

standard curve range: 10-10,000 pg/mL
(sCD137, IL-2, IP-10/CXCL10)

standard curve range: 146-150,000 pg/mL
(IL-4)

standard curve range: 15-15,000 pg/mL
(IL-21, IL-31)

standard curve range: 20-20,000 pg/mL
(FGF-2, IL-33)

standard curve range: 24-25,000 pg/mL
(IL-23)

standard curve range: 29-30,000 pg/mL
(IL-1α, IL-28A)

standard curve range: 293-300,000 pg/mL
(IL-17E/IL-25)

standard curve range: 3-3,000 pg/mL
(Eotaxin/CCL11, IL-6)

standard curve range: 4-4,000 pg/mL
(Granzyme B)

standard curve range: 7-7,000 pg/mL
(MIP-3α/CCL20)

standard curve range: 73-75,000 pg/mL
(IL-16)

standard curve range: 78-80,000 pg/mL
(Granzyme A)

standard curve range: 8-8,000 pg/mL
(sFasL)

standard curve range: 98-100,000 pg/mL
(Fractalkine/CX3CL1, IL-22, Perforin, TNFβ/LTA)

기술

multiplexing: suitable

검출 방법

fluorometric (Luminex xMAP)

배송 상태

wet ice

일반 설명

Cytokines, immunomodulatory polypeptides that play key roles in both adaptive and innate immune responses, are one of the regulatory mechanisms of the immune system. Acting at the recognition, activation or effector phases of an immune response, cytokines modulate the development and functional activities of the subtypes of T cells, B cells and myeloid cells. Since chronic inflammation and aberrant immune response contribute to many disease states, research involving cytokines and chemokines plays a significant role in achieving a deeper understanding of the etiology and progression of diseases such as infectious disease, autoimmune and chronic inflammatory disease, cardiovascular disease, metabolic syndrome, neurological disorders and cancer.

The MILLIPLEX® Non-Human Primate Cytokine Panel II is a 25 plex kit to be used for the simultaneous quantification of any or all of the following analytes in monkey serum, plasma, tissue/cell lysate and culture supernatant samples: sCD137, Eotaxin, sFASL, FGF-2, Fractalkine, Granzyme A, Granzyme B, IL-1α, IL-2, IL-4, IL-6, IL-16, IL-17A, IL-17E/IL-25, IL-21, IL-22, IL-23, IL-28A, IL-31, IL-33, IP-10, MIP-3α, Perforin, RANTES and TNFβ.

The Luminex® xMAP® platform uses a magnetic bead immunoassay format for ideal speed and sensitivity to quantitate multiple analytes simultaneously, dramatically improving productivity while conserving valuable sample volume.

Panel Type: Cytokines/Chemokines

애플리케이션

  • Analytes: sCD137, Eotaxin/CCL11, sFasL, FGF-2, Fractalkine/CX3CL1, Granzyme A, Granzyme B, IL-1α, IL-2, IL-4, IL-6, IL-16, IL-17A, IL-17E/IL-25, IL-21, IL-22, IL-23, IL-28A, IL-31, IL-33, IP-10/CXCL10, MIP-3α/CCL20, Perforin, RANTES/CCL5, TNFβ/LTA
  • Recommended Sample type: Serum, plasma, or cell culture supernatant
  • Recommended Sample dilution: 1:2 diluted plasma or serum
  • NOTE: RANTES/CCL5 is for tissue culture samples only and cannot be combined with other analytes in this panel when measuring serum or plasma due to different dilution needs
  • Assay Run Time: Overnight or one day. For best results, an overnight incubation is recommended
  • Research Category: Inflammation & Immunology

특징 및 장점

Design your multiplex kit by choosing available analytes within this panel.

성분

Non-Human Primate Cytokine Panel 2 Standard, 1 vial, lyophilized

Non-Human Primate Cytokine Panel 2 Quality Control 1, 1 vial, lyophilized

Non-Human Primate Cytokine Panel 2 Quality Control 2, 1 vial, lyophilized

Serum Matrix (0.08% Sodium Azide), 1 bottle, lyophilized

Sample Plate, 96 well format, 1 plate

2 Foil plate sealers

Assay Buffer, 2 bottles, 30 mL

Bead Diluent, 1 bottle, 3.5 mL

Wash Buffer, 10X (0.05% Proclin), 2 bottlesl, 30 mL

Non-Human Primate Cytokine Panel 2 Detection Antibodies, 1 bottle, 3.2 mL

Streptavidin-Phycoerythrin, 1 bottle, 3.2 mL

Mixing Bottle, 1 bottle

기타 정보

Please contact Technical Service for linearity of dilution.
Please note: Sample Type must be selected when configuring this kit. RANTES/CCL5 is for tissue culture samples only and cannot be combined with other analytes for serum/plasma.
Sensitivity: Refer to kit protocol for sensitivities for individual cytokines/chemokines

법적 정보

Luminex is a registered trademark of Luminex Corp
MILLIPLEX is a registered trademark of Merck KGaA, Darmstadt, Germany
xMAP is a registered trademark of Luminex Corp

신호어

Danger

유해 및 위험 성명서

Hazard Classifications

Acute Tox. 3 Dermal - Acute Tox. 4 Inhalation - Acute Tox. 4 Oral - Aquatic Chronic 2 - Eye Dam. 1 - Skin Sens. 1 - STOT RE 2

표적 기관

Respiratory Tract

Storage Class Code

6.1C - Combustible acute toxic Cat.3 / toxic compounds or compounds which causing chronic effects


시험 성적서(COA)

제품의 로트/배치 번호를 입력하여 시험 성적서(COA)을 검색하십시오. 로트 및 배치 번호는 제품 라벨에 있는 ‘로트’ 또는 ‘배치’라는 용어 뒤에서 찾을 수 있습니다.

이 제품을 이미 가지고 계십니까?

문서 라이브러리에서 최근에 구매한 제품에 대한 문서를 찾아보세요.

문서 라이브러리 방문

관련 콘텐츠

Learn the benefits of using biomarker detection multiplex immunoassays for laboratory, companion, and agricultural animal research and explore MILLIPLEX® multiplex assays for veterinary medicine and animal health research.

자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..

고객지원팀으로 연락바랍니다.