추천 제품
생물학적 소스
mouse
Quality Level
결합
unconjugated
항체 형태
purified antibody
항체 생산 유형
primary antibodies
클론
Mer590, monoclonal
분자량
calculated mol wt 110.25 kDa
종 반응성
human
포장
antibody small pack of 100 μL
기술
ELISA: suitable
activity assay: suitable
flow cytometry: suitable
western blot: suitable
동형
IgG1κ
UniProt 수납 번호
배송 상태
dry ice
저장 온도
-10 to -25°C
타겟 번역 후 변형
unmodified
유전자 정보
human ... MERTK(10461)
관련 카테고리
일반 설명
Tyrosine-protein kinase Mer (UniProt: Q12866; also known as EC:2.7.10.1, Proto-oncogene c-Mer, Receptor tyrosine kinase MerTK) is encoded by the MERTK (also known as MER) gene (Gene ID: 10461) in human. MerTK is a single-pass type I membrane glycoprotein that is synthesized with a signal peptide (aa 1-20), which is subsequently cleaved off to generate the mature form that contains an extracellular domain (aa 21-505), a transmembrane domain (aa 506-526), and a cytoplasmic domain (aa 27-999). Its protein kinase domain is localized to amino acids 587-858. MerTK is highly expressed in testis, ovary, prostate, lung, and kidney tissue. Its expression is not observed in normal B- and T-cells but is expressed in several neoplastic B- and T-cell lines. Overexpression of MerTK has also been reported in non-small cell lung cancer (NSCLC). It is involved in the regulation of cell survival, migration, differentiation, and phagocytosis of apoptotic cells. It transduces signals from the extracellular matrix into the cytoplasm by binding to several ligands, including galectin-3, Tubby protein, Tubby-related protein 1, and GAS6, a member of the Axl subfamily of receptor protein-tyrosine kinases. Ligand binding at the cell surface induces autophosphorylation of MerTK on its intracellular domain that provides docking sites for downstream signaling molecules. Its autophosphorylation on tyrosines 749, 753, and 754 in the activation loop imparts full activity. It is also autophosphorylated on tyrosine 872 that leads to recruitment of downstream partners of the signaling cascade such as phospholipase C 2. Clone Mer590 is shown to rapidly reduce total and surface expression of MerTK and prevents its phosphorylation and downstream signaling. It is also shown to enhance carboplatin induced apoptosis in Colo699 cells and diminish glioblastoma cell migration in vitro. (Ref.: Cummings, CT., et al. (2014). Oncotarget, 5(21); 10434-45; Rogers, AEJ., et al. (2012). Oncogene. 31(38): 4171 4181).
특이성
Clone Mer590 is a mouse monoclonal antibody that detects human Tyrosine-protein kinase Mer (MerTK). It targets an epitope within the extracellular domain.
면역원
Recombinant human MerTK extracellular domain/Fc chimera produced in CHO cells.
애플리케이션
Quality Control Testing
Evaluated by Flow Cytometry in A549 cells.
Flow Cytometry Analysis: 1 μg of this antibody detected MerTK in one million A549 cells.
Tested Applications
Western Blotting Analysis: A representative lot detected MerTK in Western Blotting applications (Rogers, A.E.J., et. al. (2012). Oncogene. 31(38):4171-81).
Flow Cytometry Analysis: A representative lot detected MerTK in Flow Cytometry applications. (Cummings, C.T., et. al. (2014). Oncotarget. 5(21):10434-45; Rogers, A.E.J., et. al. (2012). Oncogene. 31(38):4171-81).
Activity Assay: A representative lot of this antibody reduced surface and total MER tyrosine kinase levels in multiple cell lines. (Cummings, C.T., et. al. (2014). Oncotarget. 5(21):10434-45).
ELISA Analysis: A representative lot detected MerTK in ELISA applications (Rogers, A.E.J., et. al. (2012). Oncogene. 31(38):4171-81).
Inhibition Analysis: A representative lot of this antibody inhibited MerTyrosine kinase activity and reduced the migration of Glioblastoma multiforme cells. (Rogers, A.E.J., et. al. (2012). Oncogene. 31(38):4171-81).
Note: Actual optimal working dilutions must be determined by end user as specimens, and experimental conditions may vary with the end user
Evaluated by Flow Cytometry in A549 cells.
Flow Cytometry Analysis: 1 μg of this antibody detected MerTK in one million A549 cells.
Tested Applications
Western Blotting Analysis: A representative lot detected MerTK in Western Blotting applications (Rogers, A.E.J., et. al. (2012). Oncogene. 31(38):4171-81).
Flow Cytometry Analysis: A representative lot detected MerTK in Flow Cytometry applications. (Cummings, C.T., et. al. (2014). Oncotarget. 5(21):10434-45; Rogers, A.E.J., et. al. (2012). Oncogene. 31(38):4171-81).
Activity Assay: A representative lot of this antibody reduced surface and total MER tyrosine kinase levels in multiple cell lines. (Cummings, C.T., et. al. (2014). Oncotarget. 5(21):10434-45).
ELISA Analysis: A representative lot detected MerTK in ELISA applications (Rogers, A.E.J., et. al. (2012). Oncogene. 31(38):4171-81).
Inhibition Analysis: A representative lot of this antibody inhibited MerTyrosine kinase activity and reduced the migration of Glioblastoma multiforme cells. (Rogers, A.E.J., et. al. (2012). Oncogene. 31(38):4171-81).
Note: Actual optimal working dilutions must be determined by end user as specimens, and experimental conditions may vary with the end user
Anti-MerTK, clone Mer590, Cat. No. MABS2246, is a mouse monoclonal antibody that detects Tyrosine-protein kinase Mer (MerTK) and is tested for use in Activity Assay, ELISA, Flow Cytometry, Inhibition, and Western Blotting.
물리적 형태
Purified mouse monoclonal antibody IgG1 in PBS without azide.
저장 및 안정성
Stable for 1 year at -10°C to -25°C from date of receipt. Handling Recommendations: Upon receipt and prior to removing the cap, centrifuge the vial and gently mix the solution. Aliquot into microcentrifuge tubes and store at -20°C. Avoid repeated freeze/thaw cycles, which may damage IgG and affect product performance.
기타 정보
Concentration: Please refer to the Certificate of Analysis for the lot-specific concentration.
면책조항
Unless otherwise stated in our catalog or other company documentation accompanying the product(s), our products are intended for research use only and are not to be used for any other purpose, which includes but is not limited to, unauthorized commercial uses, in vitro diagnostic uses, ex vivo or in vivo therapeutic uses or any type of consumption or application to humans or animals.
적합한 제품을 찾을 수 없으신가요?
당사의 제품 선택기 도구.을(를) 시도해 보세요.
Storage Class Code
12 - Non Combustible Liquids
WGK
WGK 2
Flash Point (°F)
Not applicable
Flash Point (°C)
Not applicable
시험 성적서(COA)
제품의 로트/배치 번호를 입력하여 시험 성적서(COA)을 검색하십시오. 로트 및 배치 번호는 제품 라벨에 있는 ‘로트’ 또는 ‘배치’라는 용어 뒤에서 찾을 수 있습니다.
자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..
고객지원팀으로 연락바랍니다.