추천 제품
Quality Level
종 반응성
human
제조업체/상표
Milliplex®
assay range
accuracy: 105%
(TSH)
accuracy: 77%
(AGRP)
accuracy: 87%
(LH)
accuracy: 97%
(FSH)
sensitivity: 0.02 μIU/mL
(minDC+2SD; TSH)
sensitivity: 0.02 mIU/mL
(minDC+2SD; FSH)
sensitivity: 0.02 mIU/mL
(minDC+2SD; LH)
sensitivity: 1.12 pg/mL
(minDC+2SD; AGRP)
sensitivity: 2.4 pg/mL
(minDC+2SD; ACTH)
sensitivity: 6.88 pg/mL
(minDC+2SD; GH)
sensitivity: 84.42 pg/mL
(minDC+2SD; CNTF)
standard curve range: 0.024-100 mIU/mL
(FSH)
standard curve range: 0.039-160 μIU/mL
(TSH)
standard curve range: 0.049-200 mIU/mL
(LH)
standard curve range: 122-500,000 pg/mL
(CNTF)
standard curve range: 2.4-10,000 pg/mL
(AGRP)
standard curve range: 2.4-10,000 pg/mL
(GH)
standard curve range: 3.0-12,500 pg/mL
(ACTH)
inter-assay cv: <15%
intra-assay cv: <10%
(ACTH)
inter-assay cv: <15%
intra-assay cv: <10%
(AgRP)
inter-assay cv: <15%
intra-assay cv: <10%
(CNTF)
inter-assay cv: <15%
intra-assay cv: <10%
(FSH)
inter-assay cv: <15%
intra-assay cv: <10%
(GH)
inter-assay cv: <15%
intra-assay cv: <10%
(LH)
inter-assay cv: <15%
intra-assay cv: <10%
(TSH)
기술
multiplexing: suitable
검출 방법
fluorometric (Luminex xMAP)
배송 상태
wet ice
일반 설명
The MILLIPLEX® Human Pituitary Panel 1 is a 7-plex kit to be used for the simultaneous measurement of any or all of the following analytes in human serum, plasma or cell/tissue culture samples: ACTH, AGRP, CNTF, FSH, GH, LH, and TSH. This kit uses a 96-well format, contains a lyophilized standard cocktail, two internal assay quality controls and can measure up to 38 samples in duplicate.
The Luminex® xMAP® platform uses a magnetic bead immunoassay format for ideal speed and sensitivity to quantitate multiple analytes simultaneously, dramatically improving productivity while conserving valuable sample volume.
Panel Type: Endocrine
특이성
There was no or negligible cross-reactivity between the antibodies for an analyte and any of the other analytes in this panel.
애플리케이션
- Analytes: ACTH, Agouti-Related Protein (AGRP), CNTF, FSH, GH, LH, TSH
- Recommended Sample Type: Human serum, plasma, cerebrospinal fluid (CSF), tissue/cell lysates and supernatants Recommended Sample Dilution: 25 μL per well of undiluted serum or plasma. Cell/tissue culture samples may be run neat or appropriately diluted in control media
- Assay Run Time: Overnight (16-18 hr) at 2-8°C
- Research Category: Endocrine
- Research Subcategory: Metabolism
특징 및 장점
포장
저장 및 안정성
기타 정보
법적 정보
면책조항
신호어
Danger
유해 및 위험 성명서
Hazard Classifications
Acute Tox. 3 Dermal - Acute Tox. 4 Inhalation - Acute Tox. 4 Oral - Aquatic Chronic 2 - Skin Sens. 1
Storage Class Code
6.1C - Combustible acute toxic Cat.3 / toxic compounds or compounds which causing chronic effects
시험 성적서(COA)
제품의 로트/배치 번호를 입력하여 시험 성적서(COA)을 검색하십시오. 로트 및 배치 번호는 제품 라벨에 있는 ‘로트’ 또는 ‘배치’라는 용어 뒤에서 찾을 수 있습니다.
관련 콘텐츠
Multiplex toxicity assays enable researchers to simultaneously measure multiple toxicity biomarkers of various organs to gain a better understanding of toxicity. Explore how MILLIPLEX® multiplex toxicity assays are advancing research on liver injury, kidney toxicity, genotoxicity, and more.
Multiplex immunoassays, such as MILLIPLEX® multiplex metabolic assays, are critical in metabolic syndrome research because they provide a full picture of the different conditions related to it, like diabetes and obesity, as well as save time and sample volume.
자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..
고객지원팀으로 연락바랍니다.