콘텐츠로 건너뛰기
Merck
모든 사진(2)

Key Documents

HLPPMAG-57K

Millipore

MILLIPLEX® Human Liver Protein Magnetic Bead Panel - Metabolism Multiplex Assay

The Human Liver Protein Panel, using the Luminex xMAP technology, enables the simultaneous analysis of 9 liver protein biomarkers in human serum, plasma and tissue/cell culture samples.

로그인조직 및 계약 가격 보기


About This Item

UNSPSC 코드:
12161503
eCl@ss:
32161000

Quality Level

종 반응성

human

제조업체/상표

Milliplex®

assay range

accuracy: 100.2%
(HGF)

accuracy: 93.7%
(ANGPTL3)

accuracy: 94.2%
(AFP)

accuracy: 96.6%
(FGF-23)

accuracy: 96.8%
(ANGPTL4)

accuracy: 98.8%
(FGF-21)

sensitivity: 0.004 ng/mL
(MinDC+2SD; FGF-21)

sensitivity: 0.014 ng/mL
(MinDC+2SD; FGF-23)

sensitivity: 0.018 ng/mL
(MinDC+2SD; HGF)

sensitivity: 0.054 ng/mL
(MinDC+2SD; FGF-19)

sensitivity: 0.144 ng/mL
(MinDC+2SD; AFP)

sensitivity: 0.218 ng/mL
(MinDC+2SD; FABP1)

sensitivity: 0.725 ng/mL
(MinDC+2SD; ANGPTL3)

sensitivity: 0.847 ng/mL
(MinDC+2SD; ANGPTL6)

sensitivity: 2.150 ng/mL
(MinDC+2SD; ANGPTL4)

standard curve range: 0.01-10 ng/mL
(FGF-21)

standard curve range: 0.04-30 ng/mL
(FGF-23)

standard curve range: 0.07-50 ng/mL
(HGF)

standard curve range: 0.14-100 ng/mL
(AFP)

standard curve range: 0.14-100 ng/mL
(FGF-19)

standard curve range: 0.27-200 ng/mL
(FABP1)

standard curve range: 0.69-500 ng/mL
(ANGPTL3)

standard curve range: 1.37-1000 ng/mL
(ANGPTL6/AGF)

standard curve range: 5.49-4000 ng/mL
(ANGPTL4)

inter-assay cv: <20%
intra-assay cv: <10%
(AFP)

inter-assay cv: <20%
intra-assay cv: <10%
(ANGPTL3)

inter-assay cv: <20%
intra-assay cv: <10%
(ANGPTL4)

inter-assay cv: <20%
intra-assay cv: <10%
(ANGPTL6/AGF)

inter-assay cv: <20%
intra-assay cv: <10%
(FABP1)

inter-assay cv: <20%
intra-assay cv: <10%
(FGF-19)

inter-assay cv: <20%
intra-assay cv: <10%
(FGF-21)

inter-assay cv: <20%
intra-assay cv: <10%
(FGF-23)

inter-assay cv: <20%
intra-assay cv: <10%
(HGF)

기술

multiplexing: suitable

검출 방법

fluorometric (Luminex xMAP)

배송 상태

wet ice

일반 설명

Liver-secreted proteins play important roles in metabolic homeostasis through regulation of circulating lipoprotein levels, energy expenditure, glucose metabolism, and fatty acid uptake. Liver-secreted proteins may serve as biomarkers for liver diseases and gastric cancer. Accurate measurement of liver proteins is critical to obtaining an understanding of their biological functions.

MILLIPLEX® Human Liver Protein Panel is a 9-plex kit to be used for the simultaneous quantification of any or all of the following analytes in serum, plasma and tissue/cell culture samples: AFP, ANGPTL3, ANGPTL4, ANGPTL6/AGF, FABP1/L-FABP, FGF-19, FGF-21, FGF-23 and HGF.

NOTE: When assaying ANGPTL6/AGF it is recommended that serum samples be used.

This kit uses a 96-well format, contains a lyophilized standard cocktail, two internal assay quality controls and can measure up to 38 samples in duplicate.

The Luminex® xMAP® platform uses a magnetic bead immunoassay format for ideal speed and sensitivity to quantitate multiple analytes simultaneously, dramatically improving productivity while conserving valuable sample volume.

Panel Type: Metabolism

특이성

Cross Reactivty
The ANGPTL6 standard had cross reactivity with the ANGPTL4 assay of less than 2%. For all other analytes, there was no or negligible cross-reactivity between the antibodies for an analyte and any of the other analytes in this panel.

애플리케이션

  • Analytes: α-Fetoprotein (AFP), ANGPTL3, ANGPTL4, ANGPTL6 (AGF), FABP1 (L-FABP), FGF-19, FGF-21, FGF-23, HGF
  • Recommended Sample Type: Human serum, plasma, and cell/tissue culture supernatants or lysates
  • NOTE: Serum samples are recommended when measuring ANGPTL6/AGF
  • Recommended Sample Dilution: 12.5 μL per well of 1:2 diluted serum or plasma. Cell/tissue culture samples may be used undiluted or appropriately diluted in control medium.
  • Assay Run Time: Overnight (16-18 hours) at 2-8°C is recommended for optimal sensitivity. 2 hours at room temperature (20-25° C) may also be used.
  • Research Category: Metabolism
  • Research Subcategory: Metabolic Disorders

특징 및 장점

Design your multiplex kit by choosing available analytes within this panel.

포장

96 well plate
Everything you need in a single kit.

저장 및 안정성

Recommended storage for kit components is 2 - 8°C.

기타 정보

Please contact Technical Service for linearity of dilution.

법적 정보

Luminex is a registered trademark of Luminex Corp
MILLIPLEX is a registered trademark of Merck KGaA, Darmstadt, Germany
xMAP is a registered trademark of Luminex Corp

면책조항

Unless otherwise stated in our catalog or other company documentation accompanying the product(s), our products are intended for research use only and are not to be used for any other purpose, which includes but is not limited to, unauthorized commercial uses, in vitro diagnostic uses, ex vivo or in vivo therapeutic uses or any type of consumption or application to humans or animals.

픽토그램

Skull and crossbonesEnvironment

신호어

Danger

유해 및 위험 성명서

Hazard Classifications

Acute Tox. 3 Dermal - Acute Tox. 4 Inhalation - Acute Tox. 4 Oral - Aquatic Chronic 2 - Skin Sens. 1

Storage Class Code

6.1C - Combustible, acute toxic Cat.3 / toxic compounds or compounds which causing chronic effects

WGK

WGK 3


시험 성적서(COA)

제품의 로트/배치 번호를 입력하여 시험 성적서(COA)을 검색하십시오. 로트 및 배치 번호는 제품 라벨에 있는 ‘로트’ 또는 ‘배치’라는 용어 뒤에서 찾을 수 있습니다.

이 제품을 이미 가지고 계십니까?

문서 라이브러리에서 최근에 구매한 제품에 대한 문서를 찾아보세요.

문서 라이브러리 방문

Manjunath Ramanjaneya et al.
Frontiers in endocrinology, 11, 568500-568500 (2020-10-27)
Background: The fibroblast growth factors (FGF) 19 subfamily, also referred to as endocrine FGFs, includes FGF19, FGF21, and FGF23 are metabolic hormones involved in the regulation of glucose and lipid metabolism. Fetuin-A is a hepatokine involved in the regulation of
Nigel Davies et al.
Molecular therapy. Nucleic acids, 24, 369-384 (2021-04-20)
Lipid nanoparticles (LNPs) are the most clinically advanced delivery system for RNA-based drugs but have predominantly been investigated for intravenous and intramuscular administration. Subcutaneous administration opens the possibility of patient self-administration and hence long-term chronic treatment that could enable messenger

관련 콘텐츠

Multiplex immunoassays, such as MILLIPLEX® multiplex metabolic assays, are critical in metabolic syndrome research because they provide a full picture of the different conditions related to it, like diabetes and obesity, as well as save time and sample volume.

자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..

고객지원팀으로 연락바랍니다.