추천 제품
설명
HY-LiTE® Jet A1 Fuel Test Kit is suitable for rapid detection of microbiological contamination in fuel tanks
제품 라인
HY-LiTE®
유통기한
15 mo.
포장
pkg of 20 tests (20 pens, 20 large pipettes, 20 small pipettes)
제조업체/상표
HY-LiTE®
저장 조건
dry at room temperature
응용 분야
jet fuel
호환성
for use with HY-LITE®
검출 방법
bioluminescent
저장 온도
2-8°C
일반 설명
The HY-LiTE® Jet A1 Fuel Test Kit contains ready-to-use pens for detection of total biological contamination of Jet A1 fuel used in conjunction with the HY-LiTE® 2luminometer. Fuel contains small amounts of water and bears the risk of microbial contamination. Adenosine triphosphate (ATP) is detected by reaction with a luciferin/luciferase reagent in a buffered solution. The test kit is designed to indicate the presence of metabolically active biological material such as bacteria, yeast, and molds, including sulphate-reducing bacteria and other anaerobic microorganisms, which may not be detected by traditional growth-based methods.MEASUREMENT LIMITS:
IATA (International Air Transport Association) “Guidance Material on Microbiological Contamination in Aircraft Fuel Tanks” 5th Edition:
This fuel test kit contains patented capture solution for sampling from Jet A1 fuel samples.
IATA (International Air Transport Association) “Guidance Material on Microbiological Contamination in Aircraft Fuel Tanks” 5th Edition:
- Negligible: < 1000 RLU/liter fuel
- Moderate: 1000 – 5000 RLU/liter fuel
- Heavy: > 5000 RLU/liter fuel
This fuel test kit contains patented capture solution for sampling from Jet A1 fuel samples.
애플리케이션
The HY-LiTE® Jet A1 Fuel Test Kit is suitable for rapid detection of microbiological contamination in fuel tanks and distribution systems.
특징 및 장점
- Results obtained within minutes
- De-skilled method
- Field test - no need for laboratory facilities
- Quantitative, Objective results
- Numerical read-out. Easy interpretation
- Same protocol for all jet fuel samples (with / without water)
- Same action limits for all samples (with / without water)
- Detects biological activity directly in the sample and does not require the growth of microorganisms in laboratory media
- Flexible sample volume. 1 liter recommended but lower volumes can be tested. For comparison with guidelines, results can be volume adjusted: RLU/liter = RLU x (1000 ml/ml sample volume)Recommended in IATA Guidance Material on Microbiological Contamination in Aircraft Fuel Tanks 5th Ed.
적합성
For examination of biomass contamination of Jet A1 and other fuel samples
분석 메모
Packaging: Passes test
Appearance: Passes test
Performance test: Passes test
Appearance: Passes test
Performance test: Passes test
법적 정보
HY-LITE is a registered trademark of Merck KGaA, Darmstadt, Germany
Storage Class Code
12 - Non Combustible Liquids
WGK
nwg
Flash Point (°F)
Not applicable
Flash Point (°C)
Not applicable
시험 성적서(COA)
제품의 로트/배치 번호를 입력하여 시험 성적서(COA)을 검색하십시오. 로트 및 배치 번호는 제품 라벨에 있는 ‘로트’ 또는 ‘배치’라는 용어 뒤에서 찾을 수 있습니다.
자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..
고객지원팀으로 연락바랍니다.