콘텐츠로 건너뛰기
Merck
모든 사진(1)

주요 문서

122643

Millipore

ProteoExtract® Albumin/IgG Removal Kit, Maxi

로그인조직 및 계약 가격 보기


About This Item

UNSPSC 코드:
41106500

사용

sufficient for 10 sample(s) (IgG-containing; 60-180 μl each)
sufficient for 20 sample(s) (Albumin-containing; 60-180 μl each)

제조업체/상표

Calbiochem®

저장 조건

do not freeze
protect from light

입력

sample type serum
sample type plasma
sample type cerebrospinal fluid (CSF)

배송 상태

wet ice

저장 온도

2-8°C

일반 설명

High capacity, reusable columns specifically designed for the rapid and efficient removal of >80% of albumin (column 1 containing albumin-affinity resin) and IgG (column 2 containing immobilized protein A) from body fluid samples, either on an LC-instrument or manually, attached to a syringe. Removal of these high abundance proteins allows enhanced detection of low abundance proteins.

성분

Two Albumin Removal Columns, one IgG Removal Column, 10X Albumin/IgG Binding Buffer, Albumin Elution Buffer, IgG Elution Buffer, and a user protocol.

경고

Toxicity: Multiple Toxicity Values, refer to MSDS (O)

원리

The ProteoExtract Albumin/IgG Removal Kit, Maxi provides a convenient, reproducible and highly specific method to remove serum albumin and immunoglobulins from body fluid samples. The kit provides columns containing either a novel albumin-specific affinity resin or a proprietary immobilized protein A polymeric resin. These columns allow for the removal of more than 80% of both serum albumin and immunoglobulins from human body fluid samples when used according to the instructions provided in this manual. The column hardware is designed to allow for both manual and LC-instrument controlled usage. When used manually, the columns are operated as syringe-tip filters, when used with LC-instrument control, the columns can be connected to any standard HPLC/FPLC instrument via a 10/32" port using the provided adapters. For guidelines of column connections and operation, please refer to section 3 of this manual.

제조 메모

The albumin removal column contains a resin that has been optimized for the removal of albumin from human samples. However, the provided columns will also bind albumins from other species although with lower efficiency. The dynamic binding capacity of one column was determined to be 6.1 ± 0.3 mg human albumin in Binding Buffer at a flow rate of 0.1 ml/min and 10 % breakthrough. To provide guidelines for different species we have evaluated the relative amount of albumin bound to the albumin removal column (Table 2).<div class="Bio_doc_image">
Table 2: Albumin Removal Column
</div>The Binding Buffer provided with the kit has been optimized to allow for specific binding of both albumin and immunoglobulins to the respective column without requirement of buffer exchange. This allows for the subsequent use of the two types of columns either independently using the flow through of the albumin removal column as sample load for the IgG removal column or with the two types of columns being directly connected in a row.The IgG Removal Column contains Protein A which is a highly stable surface receptor produced by Staphylococcus aureus. Protein A binds the Fc portion of IgGs from a large number of species. The dynamic binding capacity of the Protein A column was determined to be 4.5 mg ± 0.2 mg human IgG in Binding Buffer at a flow rate of 0.1 ml/min and 10 % breakthrough. The provided removal columns are guaranteed to be functional as indicated when bound proteins are eluted with the provided removal buffers and columns are used according to the manufacturers instructions given in this manual.

저장 및 안정성

Upon arrival store entire contents of the kit at 4°C. Avoid freezing of the ProteoExtract Blue and ProteoExtract Protein A columns! Freezing thawing will destroy the affinity resin and the columns no longer function.

기타 정보

Boyle, M. D. P. and K. J. Reis., 1987. Biotechnology5, 697.
Due to the nature of the Hazardous Materials in this shipment, additional shipping charges may be applied to your order. Certain sizes may be exempt from the additional hazardous materials shipping charges. Please contact your local sales office for more information regarding these charges.

법적 정보

CALBIOCHEM is a registered trademark of Merck KGaA, Darmstadt, Germany
PROTEOEXTRACT is a registered trademark of Merck KGaA, Darmstadt, Germany

Storage Class Code

11 - Combustible Solids


시험 성적서(COA)

제품의 로트/배치 번호를 입력하여 시험 성적서(COA)을 검색하십시오. 로트 및 배치 번호는 제품 라벨에 있는 ‘로트’ 또는 ‘배치’라는 용어 뒤에서 찾을 수 있습니다.

이 제품을 이미 가지고 계십니까?

문서 라이브러리에서 최근에 구매한 제품에 대한 문서를 찾아보세요.

문서 라이브러리 방문

Pengchong Li et al.
Nature immunology, 22(9), 1107-1117 (2021-08-14)
The linkage between neutrophil death and the development of autoimmunity has not been thoroughly explored. Here, we show that neutrophils from either lupus-prone mice or patients with systemic lupus erythematosus (SLE) undergo ferroptosis. Mechanistically, autoantibodies and interferon-α present in the

자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..