About This Item

CAS Number:
MDL number:
UNSPSC 코드:
41115711
EC 인덱스 번호:
272-489-0
NACRES:
NB.21

제품명

EXtrelut® NT, packing material for the production of large extraction columns

Quality Level

기술

supported liquid extraction (SLE): suitable

pH

10 (20 °C, 100 g/L in H2O)

mp

>450 °C

solubility

0.0037 g/L

density

2.36 g/cm3 at 20 °C

벌크 밀도

300 kg/m3

저장 온도

15-25°C

InChI

1S/C4H9.Li/c1-3-4-2;/h1,3-4H2,2H3;

InChI key

MZRVEZGGRBJDDB-UHFFFAOYSA-N

일반 설명

Extrelut® NT simplifies liquid-liquid extraction in its most effective form by using a chemically inert, wide-pore and highly pure diatomaceous earth based solid phase. Depending on the sample volume three types of columns are available: Extrelut NT1 can take up a maximum of one ml, Extrelut NT3 three ml and Extrelut NT20 up to twenty ml of sample.

애플리케이션


  • Heart failure biomarkers BNP and NT-proBNP detection using optical labels.: This research utilizes EXtrelut NT for the extraction and analysis of heart failure biomarkers BNP and NT-proBNP. The study highlights the role of EXtrelut NT in enhancing the sensitivity and accuracy of biomarker detection using optical labels, which is critical for the early diagnosis and monitoring of heart failure (Goryacheva et al., 2022).

  • Evaluation of the Analytical Performance of BNP and NT-proBNP Assays on the Atellica CI 1900 Analyzer.: This study employs EXtrelut NT to streamline the extraction of BNP and NT-proBNP biomarkers from human plasma and serum samples. The research demonstrates the efficacy of EXtrelut NT in ensuring precise and reproducible results in high-throughput analytical workflows, validating the performance of the Atellica CI 1900 Analyzer in clinical diagnostics (Rhea-McManus et al., 2023).

  • NT-proBNP detection with a one-step magnetic lateral flow channel assay.: This study uses EXtrelut NT to facilitate the extraction and purification of NT-proBNP from whole blood samples. The research highlights the role of EXtrelut NT in achieving high sensitivity and accuracy in NT-proBNP detection using a novel magnetic lateral flow assay, which is crucial for point-of-care diagnostics of heart failure (Strohmaier-Nguyen et al., 2024).

  • Sample-to-answer lateral flow assay with integrated plasma separation and NT-proBNP detection.: This research employs EXtrelut NT in the development of a sample-to-answer lateral flow assay for NT-proBNP detection. The study emphasizes the pack′s role in ensuring efficient plasma separation and high-sensitivity detection of NT-proBNP in clinical blood samples, highlighting its application in point-of-care testing (Strohmaier-Nguyen et al., 2024).

분석 메모

Appearance: free flowing, granular powder
Bulk density: 18.0 - 36.0 g/100ml
Alkalinity (Extrelut-20-column): <0.25mmol/E-20-column
purity test
- absorbance 280 nm:
≤ 0.109
- absorbance 250 nm: ≤ 0.157
- absorbance 230 nm: ≤ 0.300
- GC: no to insignificant peaks of contamination

법적 정보

Extrelut is a registered trademark of Merck KGaA, Darmstadt, Germany

픽토그램

Health hazard

신호어

Danger

유해 및 위험 성명서

예방조치 성명서

Hazard Classifications

STOT RE 1 Inhalation

표적 기관

Lungs

Storage Class Code

6.1D - Non-combustible, acute toxic Cat.3 / toxic hazardous materials or hazardous materials causing chronic effects

WGK

WGK 1

Flash Point (°F)

Not applicable

Flash Point (°C)

Not applicable


시험 성적서(COA)

제품의 로트/배치 번호를 입력하여 시험 성적서(COA)을 검색하십시오. 로트 및 배치 번호는 제품 라벨에 있는 ‘로트’ 또는 ‘배치’라는 용어 뒤에서 찾을 수 있습니다.

이 제품을 이미 가지고 계십니까?

문서 라이브러리에서 최근에 구매한 제품에 대한 문서를 찾아보세요.

문서 라이브러리 방문

문서

Simplify your liquid-liquid extractions with our emulsion-free supported-liquid extraction (SLE) single step solution.

자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..

고객지원팀으로 연락바랍니다.