콘텐츠로 건너뛰기
Merck
모든 사진(1)

Key Documents

1.11787

Supelco

Potassium hydroxide solution

c(KOH) = 2.0 mol/l (2 N) in methanol, ready-to-use volumetric solution for titration in non-aqueous media, Titriplex®

로그인조직 및 계약 가격 보기


About This Item

UNSPSC 코드:
12352305
NACRES:
NA.21

product name

Potassium hydroxide solutionin methanol, c(KOH) = 2.0 mol/l (2 N), Titripur®

Quality Level

제품 라인

Titripur®

형태

liquid

autoignition temp.

455 °C (Methanol)

품질

Analyzed in our ISO 17025 accredited QC lab

expl. lim.

5.5-44 % (v/v) Methanol)

반응 적합성

reaction type: Acid-base reactions

농도

0.1 M

기술

titration: suitable

pH

14 (20 °C in H2O)

전이 온도

flash point 7 °C

density

0.93 g/cm3 at 20 °C

저장 온도

15-25°C

특징 및 장점

Accreditation:
This volumetric solution is analyzed by our calibration laboratory D-K-15185-01-00 which is accredited according to DIN EN ISO/IEC 17025 for analysis of amount-of-substance concentrations in volumetric solutions by DAkkS (Deutsche Akkreditierungsstelle - German National Accreditation Body). The accreditation certificate can be found at www.sigmaaldrich.com/ISO17025.

분석 메모

Form liquid
Amount-of-substance concentration 1.990 - 2.010 mol/L
Measurement uncertainty ± 0.006 mol/L
Traceability NIST SRM

The concentration is determined by volumetric titration and refers to 20°C.
The amount-of-substance concentration of this volumetric solution is traceable to a primary standard reference material (SRM) from the National Institute of Standards and Technology, Gaithersburg, USA (NIST SRM 84 potassium hydrogen phthalate) by means of volumetric standard potassium hydrogen phthalate (article number 1.02400), certified reference material according to ISO 17034, analyzed by our accredited calibration laboratory of Merck KGaA, Darmstadt, Germany according to DIN EN ISO/IEC 17025. The uncertainty is expressed as expanded measurement uncertainty with a coverage factor k=2 covering a confidence level of 95%.

Note: The titer is a correction factor to correct for variations of the volumetric solution, the titration equipment, the temperature and other laboratory conditions. For correct titration results it is recommended to determine a titer with the laboratory specific equipment and under laboratory specific conditions directly after opening a new bottle and at regular time intervals.

법적 정보

Titripur is a registered trademark of Merck KGaA, Darmstadt, Germany

신호어

Danger

Hazard Classifications

Acute Tox. 3 Dermal - Acute Tox. 3 Inhalation - Acute Tox. 3 Oral - Eye Dam. 1 - Flam. Liq. 2 - Met. Corr. 1 - Skin Corr. 1A - STOT SE 1

Storage Class Code

3 - Flammable liquids

WGK

WGK 2

Flash Point (°F)

44.6 °F

Flash Point (°C)

7 °C


시험 성적서(COA)

제품의 로트/배치 번호를 입력하여 시험 성적서(COA)을 검색하십시오. 로트 및 배치 번호는 제품 라벨에 있는 ‘로트’ 또는 ‘배치’라는 용어 뒤에서 찾을 수 있습니다.

이 제품을 이미 가지고 계십니까?

문서 라이브러리에서 최근에 구매한 제품에 대한 문서를 찾아보세요.

문서 라이브러리 방문

자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..

고객지원팀으로 연락바랍니다.