콘텐츠로 건너뛰기
Merck
모든 사진(2)

Key Documents

1.09971

Supelco

Hydrochloric acid solution

c(HCl) = 0.5 mol/l (0.5 N), concentrate for preparing 1000 mL volumetric solution for titration, Titrisol®

동의어(들):

Hydrochloric acid solution, Hydrogen chloride solution

로그인조직 및 계약 가격 보기


About This Item

실험식(Hill 표기법):
HCl
CAS Number:
Molecular Weight:
36.46
MDL number:
UNSPSC 코드:
12352301
NACRES:
NA.21

product name

Hydrochloric acid solution, for 1000 ml, c(HCl) = 0.5 mol/l (0.5 N) Titrisol®

Quality Level

제품 라인

Titrisol®

형태

liquid

반응 적합성

reaction type: Acid-base reactions

농도

0.5 M

기술

titration: suitable

pH

<1 (20 °C in H2O)

density

1.1 g/cm3 at 20 °C

저장 온도

15-25°C

SMILES string

Cl

InChI

1S/ClH/h1H

InChI key

VEXZGXHMUGYJMC-UHFFFAOYSA-N

유사한 제품을 찾으십니까? 방문 제품 비교 안내

애플리케이션


  • Research on the Synthesis of Zinc-Ammonium Phosphate Using Galvanic Waste Sludge as a Source of Zinc.: This study explored the utilization of galvanic waste sludge as a zinc source in synthesizing zinc-ammonium phosphate. Hydrochloric acid solution played a crucial role in the extraction process of zinc from the waste sludge, showcasing its application in the efficient recovery of valuable metals from industrial waste (Morgovan et al., 2024).

  • Contactless conductivity sensor employing moist paper as absorbent for in-situ detection of generated carbon dioxide gas.: This paper presents a novel analytical method using a contactless conductivity sensor with moist paper as an absorbent for detecting CO2. Hydrochloric acid solution was utilized in the calibration and preparation of the sensing materials, emphasizing its importance in developing advanced analytical techniques (Sonsa-Ard et al., 2020).

  • sym-Trisubstituted 1,3,5-Triazine Derivatives as Promising Organic Corrosion Inhibitors for Steel in Acidic Solution.: This research investigates the effectiveness of trisubstituted triazine derivatives as corrosion inhibitors for steel in hydrochloric acid solution. The study highlights the solution′s critical role in simulating industrial conditions and evaluating the inhibitors′ performance (El-Faham et al., 2016).

  • Effect of molecular structure of aniline-formaldehyde copolymers on corrosion inhibition of mild steel in hydrochloric acid solution.: The study examines how the molecular structure of aniline-formaldehyde copolymers affects their ability to inhibit corrosion in mild steel. Hydrochloric acid solution was used to create the corrosive environment, underscoring its application in corrosion studies and material testing (Zhang et al., 2015).

  • Graphene sheets modified with polyindole for electro-chemical detection of dopamine.: This paper discusses the modification of graphene sheets with polyindole to enhance the electrochemical detection of dopamine. Hydrochloric acid solution was employed in the preparation of the modified graphene sheets, demonstrating its role in nanomaterial fabrication for analytical chemistry applications (Kumar and Prakash, 2014).

법적 정보

Titrisol is a registered trademark of Merck KGaA, Darmstadt, Germany

픽토그램

CorrosionExclamation mark

신호어

Warning

유해 및 위험 성명서

Hazard Classifications

Eye Irrit. 2 - Met. Corr. 1 - Skin Irrit. 2 - STOT SE 3

표적 기관

Respiratory system

Storage Class Code

8B - Non-combustible, corrosive hazardous materials

WGK

WGK 1

Flash Point (°F)

Not applicable

Flash Point (°C)

Not applicable


시험 성적서(COA)

제품의 로트/배치 번호를 입력하여 시험 성적서(COA)을 검색하십시오. 로트 및 배치 번호는 제품 라벨에 있는 ‘로트’ 또는 ‘배치’라는 용어 뒤에서 찾을 수 있습니다.

이 제품을 이미 가지고 계십니까?

문서 라이브러리에서 최근에 구매한 제품에 대한 문서를 찾아보세요.

문서 라이브러리 방문

자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..

고객지원팀으로 연락바랍니다.