1.09074
Sulfuric acid solution
c(H₂SO₄) = 0.05 mol/l (0.1 N), reag. USP, ready-to-use volumetric solution for titration, Titriplex®
동의어(들):
Sulfuric acid solution
About This Item
추천 제품
제품명
Sulfuric acid, c(H2SO4) = 0.05 mol/l (0.1 N), Titripur®, reag. USP
Agency
reag. USP
suitable for SM 2310
suitable for SM 2320
Quality Level
제품 라인
Titripur®
양식
liquid
품질
Analyzed in our ISO 17025 accredited QC lab
반응 적합성
reaction type: Acid-base reactions
포장
Titripac® of
농도
0.05 M
기술
titration: suitable
pH
1.3 (20 °C in H2O)
density
1.00 g/cm3 at 20 °C
저장 온도
15-25°C
SMILES string
OS(O)(=O)=O
InChI
1S/H2O4S/c1-5(2,3)4/h(H2,1,2,3,4)
InChI key
QAOWNCQODCNURD-UHFFFAOYSA-N
유사한 제품을 찾으십니까? 방문 제품 비교 안내
애플리케이션
- Cellulose Nanocrystals and Lignin Nanoparticles Extraction from Lemna minor L.: Acid Hydrolysis of Bleached and Ionic Liquid-Treated Biomass.: This research explores the extraction of cellulose nanocrystals and lignin nanoparticles using sulfuric acid hydrolysis, highlighting its significance in developing sustainable biomaterials (Puglia et al., 2024).
- Production and Characterization of Nanocellulose from Maguey (Agave cantala) Fiber.: The study utilizes sulfuric acid for the production and characterization of nanocellulose from Maguey fiber, underscoring its potential in advancing biocomposites (Sumarago et al., 2024).
- Stability and Structure of Potentially Atmospherically Relevant Glycine Ammonium Bisulfate Clusters.: This paper investigates the stability and structure of glycine ammonium bisulfate clusters, providing insights into atmospheric chemistry and the role of sulfuric acid in aerosol formation (Hariharan et al., 2024).
- Nanostructured Niobium and Titanium Carbonitrides as Electrocatalyst Supports.: Examines the use of sulfuric acid in synthesizing nanostructured niobium and titanium carbonitrides, essential for improving electrocatalyst supports in energy applications (McLeod et al., 2024).
- Synthesis and characterization of hydroxyapatite nanoparticles from calcium hydroxide fouled with gases evolved from smokestack of glass industry.: This research focuses on the synthesis of hydroxyapatite nanoparticles using sulfuric acid, showcasing its utility in recycling industrial waste (Abdelmoaty & Mousa, 2024).
특징 및 장점
This volumetric solution is analyzed by our calibration laboratory D-K-15185-01-00 which is accredited according to DIN EN ISO/IEC 17025 for analysis of amount-of-substance concentrations in volumetric solutions by DAkkS (Deutsche Akkreditierungsstelle - German National Accreditation Body). The accreditation certificate can be found at www.sigmaaldrich.com/ISO17025.
포장
Titripac® packaging - all SKU-pack size numbers ending "4000, 4003, 9010, 9013" - more information on www.sigmaaldrich.com/Titripac
결합
분석 메모
Amount-of-substance concentration 0.04975 - 0.05025 mol/L
Measurement uncertainty ± 0.00015 mol/L
Traceability NIST SRM
The concentration is determined by volumetric titration and refers to 20°C.
The amount-of-substance concentration of this volumetric solution is traceable to a primary standard reference material (SRM) from the National Institute of Standards and Technology, Gaithersburg, USA (NIST SRM 723 Tris(hydroxymethyl)aminomethane) by means of volumetric standard Tris(hydroxymethyl)aminomethane (article number 1.02408), certified reference material according to ISO 17034, analyzed by our accredited calibration laboratory of Merck KGaA, Darmstadt, Germany according to DIN EN ISO/IEC 17025. The uncertainty is expressed as expanded measurement uncertainty with a coverage factor k=2 covering a confidence level of 95%.
Note: The titer is a correction factor to correct for variations of the volumetric solution, the titration equipment, the temperature and other laboratory conditions. For correct titration results it is recommended to determine a titer with the laboratory specific equipment and under laboratory specific conditions directly after opening a new bottle and at regular time intervals.
법적 정보
관련 제품
신호어
Warning
유해 및 위험 성명서
예방조치 성명서
Hazard Classifications
Met. Corr. 1
Storage Class Code
8B - Non-combustible, corrosive hazardous materials
WGK
nwg
Flash Point (°F)
Not applicable
Flash Point (°C)
Not applicable
시험 성적서(COA)
제품의 로트/배치 번호를 입력하여 시험 성적서(COA)을 검색하십시오. 로트 및 배치 번호는 제품 라벨에 있는 ‘로트’ 또는 ‘배치’라는 용어 뒤에서 찾을 수 있습니다.
문서
SmartChemicals enable wireless transfer of CoA data stored on an RFID tag on the consumable bottle to the titrator, reducing effort and chance for human error. Crucial data required for the application is transmitted safely, reliably and intelligently to the instrument.
자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..
고객지원팀으로 연락바랍니다.