추천 제품
product name
Calconcarboxylic acid, metal indicator
Quality Level
형태
solid
기술
titration: suitable
mp
300 °C
벌크 밀도
400 kg/m3
저장 온도
2-30°C
InChI
1S/C21H14N2O7S/c24-16-10-17(31(28,29)30)13-7-3-4-8-14(13)18(16)22-23-19-12-6-2-1-5-11(12)9-15(20(19)25)21(26)27/h1-10,24-25H,(H,26,27)(H,28,29,30)
InChI key
MVQBFZXBLLMXGS-UHFFFAOYSA-N
애플리케이션
- Solid-state polymer membranes for simple, sensitive, and low-cost monitoring of mercury in water.: This study utilizes calconcarboxylic acid in solid-state polymer membranes to monitor mercury in water. The method offers a simple, sensitive, and cost-effective approach for environmental monitoring, highlighting the potential for widespread application in water quality assessment (Kallithrakas-Kontos et al., 2019).
- A new fluorescent quenching method for the determination of phosphoproteins by using calconcarboxylic acid.: This research introduces a fluorescent quenching method using calconcarboxylic acid for the determination of phosphoproteins. The technique is significant for proteomics and biochemical research, providing a new tool for protein analysis (Zhu et al., 2015).
- Formation of new non-oxido vanadium(IV) species in aqueous solution and in the solid state by tridentate (O, N, O) ligands and rationalization of their EPR behavior.: Calconcarboxylic acid is used as a ligand to form non-oxido vanadium(IV) species. This study enhances the understanding of vanadium chemistry and its potential applications in catalysis and materials science (Sanna et al., 2013).
- Electrophoretic nanotechnology of composite electrodes for electrochemical supercapacitors.: This paper explores the use of calconcarboxylic acid in the fabrication of composite electrodes for supercapacitors. The findings are crucial for the development of high-performance energy storage devices (Su and Zhitomirsky, 2013).
분석 메모
Appearance of solution: passes test
Water (according to Karl Fischer): ≤ 9
Suitability as indicator (for metal titration): passes test
Water (according to Karl Fischer): ≤ 9
Suitability as indicator (for metal titration): passes test
신호어
Warning
유해 및 위험 성명서
Hazard Classifications
Eye Irrit. 2 - Skin Irrit. 2 - STOT SE 3
표적 기관
Respiratory system
Storage Class Code
11 - Combustible Solids
WGK
WGK 3
Flash Point (°F)
Not applicable
Flash Point (°C)
Not applicable
시험 성적서(COA)
제품의 로트/배치 번호를 입력하여 시험 성적서(COA)을 검색하십시오. 로트 및 배치 번호는 제품 라벨에 있는 ‘로트’ 또는 ‘배치’라는 용어 뒤에서 찾을 수 있습니다.
자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..
고객지원팀으로 연락바랍니다.