V-011
Retinol solution
100 μg/mL ± 25% (Refer to COA) (Ethanol with 0.1% (w/v) BHT), ampule of 1 mL, reference material, Cerilliant®
동의어(들):
Retinol solution, 3,7-Dimethyl-9-(2,6,6-trimethyl-1-cyclohexenyl)-2,4,6,8-nonatetraen-1-ol, Axerophthol, Vitamin A alcohol solution, Vitamin A1, all-trans-Retinol
About This Item
추천 제품
Grade
reference material
형태
liquid
특징
(Snap-N-Shoot®)
(Snap-N-Spike®)
포장
ampule of 1 mL
제조업체/상표
Cerilliant®
농도
100 μg/mL ± 25% (Refer to COA) (Ethanol with 0.1% (w/v) BHT)
응용 분야
clinical testing
clinical testing
형식
single component solution
저장 온도
−70°C
SMILES string
CC(=C/CO)\C=C\C=C(C)\C=C\C1=C(C)CCCC1(C)C
InChI
1S/C20H30O/c1-16(8-6-9-17(2)13-15-21)11-12-19-18(3)10-7-14-20(19,4)5/h6,8-9,11-13,21H,7,10,14-15H2,1-5H3/b9-6+,12-11+,16-8+,17-13+
InChI key
FPIPGXGPPPQFEQ-OVSJKPMPSA-N
유사한 제품을 찾으십니까? 방문 제품 비교 안내
애플리케이션
- Enhancing cell culture systems: Research highlights the potential of Retinol as an essential component in cell culture systems, enhancing cell proliferation and differentiation. This supports its use in high-purity Retinol cell culture supplement applications (Ke et al., 2024).
- Stabilized Retinol in dermatological applications: A study on topical 0.1% stabilized Bioactive Retinol demonstrates its efficacy and tolerability for treating photoaging, indicating its potential as a high-purity Retinol reagent for skin care research (Farris et al., 2024).
- Drug-nutrient interaction research: Investigation into the interaction between Retinol and pharmaceuticals, like Acetylsalicylic Acid and Warfarin, provides insights into its role in vitamin-based assays, contributing to safer pharmacological studies involving Retinol-based assays (Renaud et al., 2024).
- Assessment of Retinol signaling pathways: An in silico and in vitro approach examines natural ligands for receptors influenced by Retinol, aiding in the study of Retinol signaling pathways and its application as a research reagent in environmental safety (Choi et al., 2024).
특징 및 장점
- Fully characterized under ISO/IEC 17025 and ISO 17034 accreditation
- Accompanied with a comprehensive Certificate of Analysis (CoA) with data on stability, homogeneity, accuracy of concentration, uncertainty, and traceability
- Rigorously tested through real-time stability studies to ensure accuracy and shelf life
- Gravimetrically prepared using qualified precision balances to ensure minimal uncertainty
- Flame sealed under argon into ampoules for long-term shelf life
- Offered in a convenient, DEA-exempt format to improve laboratory efficiency
법적 정보
관련 제품
신호어
Danger
유해 및 위험 성명서
Hazard Classifications
Eye Irrit. 2 - Flam. Liq. 2
Storage Class Code
3 - Flammable liquids
WGK
WGK 1
Flash Point (°F)
57.2 °F
Flash Point (°C)
14.0 °C
시험 성적서(COA)
제품의 로트/배치 번호를 입력하여 시험 성적서(COA)을 검색하십시오. 로트 및 배치 번호는 제품 라벨에 있는 ‘로트’ 또는 ‘배치’라는 용어 뒤에서 찾을 수 있습니다.
이미 열람한 고객
프로토콜
Separation of δ-Tocopherol, analytical standard; Retinyl acetate; (+)-γ-Tocopherol; α-Tocopherol, ≥95.5%; Retinol; Vitamin A (acetate), meets USP testing specifications
자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..
고객지원팀으로 연락바랍니다.